Test Failed
RF MS TX Rho PCS CH600
RF MS RX FER PCS CH600
RF MS RX FER CELL CH384
RF MS SINAD
RF GPS Test Mode 3
RF MS TX Limiting Po PCS CH25
RF MS TX Limiting Po CELL CH1013
Issue 2 09/2005
What to Check
Rho problem is very likely caused by elevated spurious
levels in UHF LO and/or by VHF Tx LO in N601. Establish
a call and verify the degraded Rho. Next probe the LO
output for spurs.
At this stage, FER is most likely caused by a poor RF
connection. Perform a conductive RSSI measurement
with sector power at -65dBm (low LNA gain) and -
100dBm (high LNA gain).
At this stage, FER is most likely caused by a poor RF
connection. Perform a conductive RSSI measurement
with sector power at -65dBm (low LNA gain) and -
100dBm (high LNA gain).
SINAD is measurement of a mobile terminal's audio
quality in an AMPS call. Hence, a secured audio plug is
needed to be checked for any connection problem.
Verify this on the bench in an AMPS call.
Inject signal and test SNR with the GPS self-test. If
SNR is out-of-limits, then probe chain.
Tx limiting power is most likely caused by a poor RF
connection.
Tx limiting power is most likely caused by a poor RF
connection.