Cdma In Call Testing (Low Gain) - Nokia RM-11 Series Troubleshooting Manual

Rf
Hide thumbs Also See for RM-11 Series:
Table of Contents

Advertisement

RM-11
Troubleshooting - RF

CDMA In Call Testing (Low Gain)

AGC Tolerances
Band
Cell CDMA
PCS CDMA
1. In a call, handoff to the center channel (channel 600 for PCS, or channel 384 for
Cell) and verify that the call box sector power is –65dBm. The LNA will be in Low
Gain.
2. Compare the RSSI reading on the RF AGC Status dialog box with the sector
power. Compare the Tx power to the digital average power on the call box. The
value should be accurate to +3dBm.
3. Verify that Cell PDMs for Rx and Tx are within the specified tolerances:
Cell: Tx power (dBm) = -73 — RSSI
PCS: Tx power (dBm) = -76 — RSSI
©2005 Nokia Corporation
Page 16
Rx AGC
IF AGC
>40
<40
>40
<40
Confidential
CC Technical Documentation
RF AGC
PA AGC
125+-30
<-300
120+-30
<-300
Issue 2 09/2005

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents