7.3. Installation of operation mode of safety inputs
Action
1. Input the device in programming mode of safety sensor
1) input in the PM of remote controls: press and hold
the programming button for more than 4 sec.;
2) input in PM of operation modes: press and hold
the programming button for more than 1 sec.;
3) input in PM of safety sensor: press short the
programming button.
2. Change the operation mode of safety inputs
The modes are switched circle-wise each time you
press and hold the programming mode for more than
1 sec. (up to yellow flash).
3. Reset the operation mode of safety inputs to the factory setting
Press and hold the programming button for more than
4 sec.
4. Output the device from the programming mode
Press shortly the programming button.
The device is automatically removed from the programming mode, if no
actions are performed with it during 32 sec.
8. Retransmission
The retransmission function is necessary to increase the transmission distance of a remote
control signal in difficult reception conditions. Difficult conditions can be strong interference,
long distance, the presence of a large number of obstacles. For example, to control a group of
devices located on an object with difficult reception conditions, you need to record the remote
control in all devices and turn on the retransmission function on one or more of them. Devices
intended for retransmission are selected based on the size and characteristics of an object. As
a rule, the repeater should be located in the middle of the distance, between the most remote
control points of the receiver.
Only the dynamic code is retransmitted!
Do not turn on the retransmission without extreme necessity.
Do not turn on the retransmission on devices located nearby.
Do not turn on the retransmission on many devices. This can disturb to transmit
the second command of the remote control coming after a short period of time
(1-2 sec.).
Retransmission of remote control marking is carried out only together with the
control of power relay.
Indication
1) visual indicator blinks red;
2) visual indicator blinks green.
3) visual indicator blinks red for
certain times (cl. 2).
Number of flashes:
1- NO – "STOP" command
(factory setting);
2- NO – "STOP-UP" command;
3- NC – "STOP" command;
4- NC – "STOP-UP" command;
5- control of group of devices.
Single red flash.
The visual indication stops.
8.1. Turning on/off the retransmission function
Action
1. Input the device in programming mode of repeater from the standby-mode
Press and hold the programming button for more
than 8 sec.
2. Change the operation mode of repeater
Turning on/off the retransmission mode is carried
out circle-wise each time you press and hold the
programming mode for more than 1 sec. (up to
yellow flash).
3. Output the device from the programming mode
Press shortly the programming button.
The device is automatically removed from the programming mode, if no
actions are performed with it during 32 sec.
9. Device operation
The device can execute the following commands:
1. "UP", "DOWN", "STOP" - when controlling from the Radio 8101-5 remote control. If
during the movement of the roller shutter you press the button of the opposite direction and
hold it for more than 1 sec, the roller shutter will stop for a while and start moving in the
opposite direction.
2. "UP", "DOWN", "STOP" - when controlling by using the Radio 8101-2M mini-remote
controls, as well as the Radio 8152-50 timer.
3. "Step-by-step control" - when controlling by using the Radio 8101-1M, Radio 8101-4M
mini-remote controls.
In the "Roller shutter mode with auto closing" operation mode, the device can be blocked for
3 hours from the previously recorded remote control. To do this, press and hold the remote
control button for more than 4 seconds. It can be unlocked by pressing any remote control
button from which the device was blocked, or by pressing a button on the connected key switch.
10. Current maintenance
If during operation the device fault is detected it is necessary to disconnect the device from the
supply mains immediately and call maintenance personnel. Within the warranty period
servicing and repair are provided by the manufacturer dealer.
11. Storage and transportation, service life
The devices should be stored in packing at temperatures from +5°C to +40°C and relative
humidity of not more than 80% in heated and vented warehouses, in air-conditioned depots
without corrosive contaminants, conductible dust, acid and alkali vapors and gases causing
corrosion and insulation breakdown.
Indication
Visual indicator blinks green for
certain times.
Number of flashes:
1- retransmission of command is off
(factory setting);
2- retransmission of command is on.
The visual indication stops.