Fig. 4 Connection of reed switch
Fig. 5 Connection of optical sensor SIGNAL12
Fig. 6 Connection of infrared barrier
7.2. Group control of devices
You can use NO or NC contact type to control the devices.
A jumper between the contacts 13-15 allows you to invert the effect of the device on the roller
shutter.
Device Radio 8113 IР65 or another power supply can serve as a 12 V power supply.
For example, if you use the NC-contact, then this connection scheme will support the
monitoring of control line integrity. When a wire breaks, all roller shutters will raise/lower as
if the control contact is opened. It is necessary to set the 5th operation mode of the safety inputs
to implement this functionality (cl. 6.3).
7.2.1. Control of group of devices, a jumper is not installed (fig. 7)
- when the contact is closed, the device will execute the "DOWN" command, the control from
the remote controls and key switch will be blocked;
- when the contact is opened, the device will execute the "UP" command, the control from the
remote controls and key switch will be available;
- after power re-supplying when the contact is opened, the device will execute the "UP"
command;
- after power re-supplying when the contact is closed, the device will execute the "DOWN"
command.
+12 V - brown;
output - green;
general - white
7.2.2. Control of group of devices, a jumper 13-15 is installed
12 V
12 V
- when the contact is closed, the device will execute the "UP" command, the control from the
remote controls and key switch will be available;
- when the contact is opened, the device will execute the "DOWN" command, the control from
the remote controls and key switch will be blocked;
- after power re-supplying when the contact is opened, the device will execute the "DOWN"
command;
- after power re-supplying when the contact is closed, the device will execute the "UP"
command.
Inadvertent activation is possible with a large length of the control line and
significant settings to it. Division of the control line into two with coupling of 12
V intermediate relay can serve as the solution of a problem. You should use the
power supply from different devices Radio 8113 IP65 for each line.
Fig. 7 Variant of control without a jumper
Fig. 8 Variant of control with a jumper