Download Print this page

Nero Radio 8113 IР65 Manual page 3

Executive device

Advertisement

6.1. Change of operation mode, command time and auto closing time
Action
1. Input the device in programming mode of operation modes
1) input in the PM of remote controls: press and hold the
programming button for more than 4 sec.;
2) input in PM of operation modes: press and hold the
programming button for more than 1 sec. (up to yellow
flash).
2. Change the device operation mode
The modes are switched circle-wise each time you press
and hold the programming button for more than 1 sec. (up
to yellow flash).
3. Change the command time (in the PM of operation mode)
The time setting is carried out only using connected key switch without the
fixation of pressed position.
1) to input repeatedly the device in the PM of operation
mode, if it is necessary;
nd
2) to set the 2
operation mode;
3) to install the roller shutter in the lowermost position by
pressing the "DOWN" button;
4) to start the time countdown by pressing shortly the "UP"
button;
5) to wait for 3-5 sec. and press the "DOWN" button when
the roller shutter is stopped in uppermost position. New
time will be recorded in the device memory.
4. Change the time of auto closing timer (in the PM of operation mode)
1) to input repeatedly the device in the PM of operation
mode, if it is necessary;
2) to set the 3rd operation mode;
3) to start the time countdown by pressing shortly the "UP"
button;
4) to press the "DOWN" button when the necessary time is
expired. New time will be recorded in the device memory.
5. Reset to the factory setting (in the PM of operation mode)
1) to input repeatedly the device in the PM of operation
mode, if it is necessary;
2) press and hold the programming button for more than 4
sec.
6. Output the device from the programming mode
Press twice shortly the programming button.
Indication
7. Safety inputs
1) visual indicator blinks
7.1. Connection of safety devices
red;
2) visual indicator blinks
The device can operate with the following safety devices:
green for certain times.
- reed switch (fig. 4);
- optical sensors SIGNAL12 (fig. 5);
- infrared barrier with NO and NC contacts (fig. 6);
Number of flashes:
- device for group opening of roller shutters with NO and NC contacts (clause 6.2).
1- short command mode;
2- roller shutter mode
When the device is blocked by the sensor, the red visual indicator will flash continuously. The
(factory setting);
device will be unavailable to control. In this situation, it is necessary to eliminate the obstacle
3- roller shutter mode with
in the operation area of the sensor or to change the operation mode in accordance with the
auto closing;
connected sensor.
4- continuous command
mode.
The device has 5 operation modes of safety inputs (PM of safety inputs) for the organization
of work with the safety elements.
Modes 1-4 determine the contact type of the infrared barrier (reed switch) and the response of
the device when sensors are blocked during the movement:
The visual indication of the
1. NO-sensor: when the device is closed, it will execute the "STOP" command.
second operation mode –
2. NO-sensor (factory setting): when the device is closed, it will execute the "STOP"
double green flashes.
and "UP" commands.
3. NC-sensor: when the device is opened, it will execute the "STOP" command.
4. NC-sensor: when the device is opened, it will execute the "STOP" and "UP"
commands.
When the IS15 insertion is deformed, the optical beam of the optical sensors SIGNAL12 is
interrupted, and the device always executes the "STOP" and "UP" commands. The response
does not depend on the selected mode (1-4). The "UP" command is executed only when the
sensor is blocked during the "DOWN" movement.
The visual indication of the
third operation mode –
The fifth mode allows you to control groups of devices Radio 8113 IР65 through one dry
triple green flashes.
contact by applying / dumping power supply +12 V (cl. 6.2).
The visual indicator will
flash yellow after 1 and 4
sec., and then it will
continue to blink double
green light.
The visual indication stops.
The device is automatically removed from the programming mode, if no
actions are performed with it during 32 sec.

Advertisement