Mitsubishi Electric FR-A8AY Instruction Manual page 22

Hide thumbs Also See for FR-A8AY:
Table of Contents

Advertisement

Pr.309
setting
value
1
Outputs separate selection signals from the
voltage output terminal (AM0) and the current
output terminal (AM1).
11
NOTE
• "Analog output" means the voltage (0 to 10 V) and current (0 to 20 mA) output from terminals AM0 and AM1; while
"output signal" indicates the monitor signal (refer to
Description
Parameter setting
Terminal
Pr.310:
Selects the output signal.
Pr.311:
Output signal value when analog
AM0
output is zero.
Pr.312:
Output signal value when analog
output is at maximum.
Pr.306:
Selects the output signal.
Pr.307:
Output signal value when analog
AM1
output is zero.
Pr.308:
Output signal value when analog
output is at maximum.
Pr.310:
Selects the output signal.
Pr.311:
Analog output value when output
AM0
signal is zero.
Pr.312:
Analog output value when output
signal is at maximum.
Pr.306:
Selects the output signal.
Pr.307:
Analog output value when output
AM1
signal is zero.
Pr.308:
Analog output value when output
signal is at maximum.
page
26) set in parameters Pr.306 and Pr.310.
Calibration
parameter
Pr.323
C0 (Pr.900)
Pr.324
C1 (Pr.901)
Pr.323
C0 (Pr.900)
Pr.324
C1 (Pr.901)
ANALOG OUTPUT
4
23

Advertisement

Table of Contents
loading

Table of Contents