Point 4a – Input from Other Connect Products (Projection Screen)
The Left RJ11 Input allows you to daisy chain from another connect module eg: Electricinema Projection Screen and have both
products controlled via the IR remote control
Point 4b – Output to Other Connect Products
The Right RJ11 output allows you to daisy chain to another connect module eg: Electricinema Projection Screen and have both
products controlled via the IR remote control.
Note: Connection must be from the right RJ11 output to the left RJ11 Input up to 9 Modules in Total
Right RJ11 Output
to connect modules
Point 5 – Connection of Low Voltage Trigger Module (Not Supplied)
The Left RJ11 Input allows you to connect the Low Voltage Trigger Module, the module requires 5V – 24V DC to operate. When DC
voltage is supplied to Low Voltage Trigger from a projector or control system the projector lift will lower and when no DC voltage is
present the projector lift will raise.
Note: The Low Voltage Trigger must be connected to the Left RJ11 using 6 Core Flat Cable to first Connect Module.
5V – 24V
DC Input
Once you have chosen your switching method ensure that you refit the lid of the control box before applying mains power to the
Projector Lifter.
Left RJ11 Input from
previous module