Motor Wiring
Pin 1 - Brow n Screen Dow n
Pin 2 - Black Screen Up
Pin 3 - Yellow /Green Earth
Pin 4 - Blue Neutral
2
IR Receiver
3
Infra Red
Receiver
Point 1 The AV Lift comes wired with a standard 3 pin power plug which is suitable for Australian and New Zealand GPO's (general
power outlet).
Point 2 Infra‐Red Remote Control
The AV Lift is packaged with a 2 channel Infra Red Transmitter and a
300mm long IR Sensor, for connection to the Connect Module.
Position the IR Sensor Eye with double sided tape or a U Pin, so that it can
be seen from where you wish to operate the AV Lift, and use the up and
down buttons on the transmitter on channels 2 only to operate the unit.
Point 3a ‐ Impulse Wall Switch (supplied Separately‐ Item Number 3500998).
The Connect Module equipped Projector Lifter can also have simple wall switch operation, although due to interior décor choices the
actual switch itself is not supplied with the AV Lift and needs to be sourced.
You will need to connect the impulse wall switch to the dry contact closure input, it provides local control of your Projector Lifter
Point 3b ‐ Dry Contact Closure
This is the industry standard method of switching an AV Lifter via a Building Control System.
It is operated on a SPDT (single pole double throw) switching standard with an Open, Close and Common
input port. It utilises the same connection as the above described Impulse Wall Switch.
1
M
240 V
Input
IEC
1
2
3
4
Socket
M otor Output
Connect Netw ork
Contact Close
Out
In
Input
D
C
U
Input
LED
RJ12 Connector
6 Core w ired
straight through
5
D ow n
Up
M om entary Contact Close
Next Connect M odule
M axim um 9 Modules
4
Connect Netw ork
In
Out
In
Out