Restoring to factory default values

Main Unit
Performing the following operation will remove all updates and restore the factory default
settings.
Required devices
USB keyboard
USB mouse
HDMI display or DisplayPort display
1.
Connect a USB keyboard and display to the unit.
2.
Immediately after powering on the unit, repeatedly press the Delete key on the keyboard
until the BIOS password screen appears.
3.
Enter the password on the BIOS password entry screen to display the BIOS screen.
This password is set by the user. If the password has not been changed from the default
setting, change the password as described in "Changing the Default Password" (page 55).
4.
Change "Boot Option #1" in the [Boot] menu to "Acronis Loader."
5.
Select "Save changes and reset" from the [Save & Exit] menu.
6.
The unit starts rebooting. Repeatedly press the "0" (zero) key on the keyboard until the
password entry screen appears.
7.
Enter "sonypsg" on the password entry screen.
The recovery process begins, and the unit turns off automatically when finished.
8.
Turn the unit on.
9.
Press the "c" key on the keyboard when the following message appears.
The unit reboots.
10. After the system finishes booting, turn off the unit.
11. Turn the unit on.