Service Software Instructions
RSSI Analog... command
Activation
Alt, T, N
This function is used for tuning analog RSSI.
The next automatic selections are made when this tuning function is acti-
vated:
Values from EEPROM is shown and the measurement is started when the
"meas" button is pressed and it is executed in five steps:
1. User is requested to put signal generator input level –113 dB and fre-
quency 879.300 MHz
2. Measurement with input level is executed
3. User is requested to put signal generator input level –51 dB and fre-
quency 879.300 MHz
4. Measurement with input level is executed
5. The RSSI tuning dialog will be updated when previous steps are done
Page 36
Status Bar Text
Open the Tuning RSSI dialog box
– Active Unit = RX
– Operation Mode = analog
– Power Level OFF
– Channel 300
– Low band