NYCe 4000 Multi-axis motion control
system
"DRV" LED indication
(visible color)
Red continuously
Orange continuously
Green continuously
Tab. 13-1: "DRV" LED status
The "NET" LED shows the status of the microprocessor and the SERCOS III
network connected to the SERCOS III Master module.
"NET" LED indication
(visible color)
Off
Orange continuously
Green continuously
Red flashing
Tab. 13-2: "NET" LED status
On the NYM04.1-SE3-MAST-NY4150/10 two LEDs for information indication of
the SERCOS ring are mounted underneath the RJ45 sockets. The left (orange)
LED indicates that data is transported over the Ethernet connection. The right
(green) LED indicates that the Ethernet cable is correctly connected.
See the NYCe 4000 Hardware System Manual for more information.
If the NYCe 4000 software is installed on the PC and the PC is connected to the
Motion Control Unit, you can start the NYCeConfigurator program and download
the required gateware. See the NYCe 4000 Tools Manual for more information.
14 IT-security
The
operation
of
implementation of an integral concept for state-of-the-art IT security. Bosch
Description
Default setting when the SERCOS III Master module starts, power up.
Fatal error on the SERCOS III Master module, or gateware or microware
or SERCON100M is not or not correctly loaded, or module not
operational, because a communication problem is detected.
The NYM04.1-SE3-MAST-NY4150/10 is only supported in NYCe 4000
Software Release 40V00 or higher.
Gateware, microware and SERCON100M loaded, but node not yet
operational, because other drive modules in the node are initializing.
SERCOS III Master module OK.
Description
Microprocessor not (yet) started. The MCU is starting, and has not yet
started the microprocessor.
After downloading new software to flash memory of the
microprocessor a reset is required to start the new software.
During the power-up of the microprocessor, POST (Power On Self
Test), or downloading software or SERCON100M bitfile.
SERCOS III network is ready.
The SERCOS III network is not ready. Cables not connected, loop not
closed, IndraDrive not powered or network is being enumerated.