Norgren 82 Series Installation And Maintenance Instructions

Norgren 82 Series Installation And Maintenance Instructions

3/2 valves

Advertisement

Quick Links

Excelon
Plus 3/2 VALVES
®
Air Preparation Range
1/4", 3/8" 82 Series
3/8", 1/2", 3/4" 84 Series
Installation and Maintenance Instructions
For further information and other languages scan this QR code or visit:
DE – Für weiterführende Informationen diesen QR-Code scannen oder siehe:
ES – Para más información y otros idiomas, escanear este código QR o visitar:
FR – Pour plus d'informations et d'autres langues, consultez ce code QR ou visitez:
IT – Per ulteriori informazioni e altre lingue scansionare questo QR code o visitare:
PT – Para mais informação e outros idiomas scanea este código QR ou visite a:
RU – Для получения более подробной информации, в том числе на других языках,
TECHNICAL DATA
Fluid:
Maximum supply pressure:
Operating temperature*:
Typical flow @ P1=6.3 bar
(90 psi) & 0.5 bar (7.25 psi)
pressure drop:
Typical exhaust flow @ P1
= 6.3 bar (90 psi) & 0.5 bar
(7.25 psi) pressure drop:
Air quality:
Port threads:
Exhaust port threads:
Thread forms:
Materials:
CN – 欲了解更多信息和其他 言版本 :
пожалуйста, отсканируйте QR код или посетите :
https:/ /www.norgren.com/excelon-plus
Compressed air
10 bar (145 psig)
-20 °C to +65 °C (-4 °F to +149 °F)
*Air supply must be dry enough to
avoid ice formation at temperatures
below +2 °C (+35 °F)
82 Series: 20.7 dm3/s (44 scfm)
84 Series: 50 dm3/s (106 scfm)
82 Series: 22.2 dm3/s (47 scfm)
84 Series: 60 dm3/s (127 scfm)
ISO 8573-1 Class 7:4 - or better
82 Series: 1/4", 3/8"
84 Series: 3/8", 1/2", 3/4"
82 Series: 1/4"
84 Series: 1/2"
ISO G, PTF
Body: Aluminum
End Caps: Aluminum
Body Covers: ABS
Elastomers - NBR
Valve - Brass
GENERAL INSTALLATION
GI-1
Always turn off and exhaust air pressure
prior to installing and servicing units.
Ensure that the air is completely exhausted
prior to beginning any actions.
GI-2
Always ensure power is removed from electrical
circuit prior to installing and servicing units.
GI-3
Electrical connections should only be made by personnel
trained and authorized to perform these operations.
GI-4
Connect piping to ports using pipe thread sealant using
pipe thread sealant on male threads only. Do not allow
sealant to enter the interior of the unit. Units should be
installed with air flow in the direction of the arrow on the
body and as close as possible to the device being serviced.
GI-5
For ISO G threads do not install fittings that are longer
than 13mm for 84 Series and 10mm for 82 Series
GI-6
For Soft Start Valves install only into applications
where the downstream pressure can build up
during the initial safe pressure build up stage.
GI-7
Install exhaust silencers, with flow rating greater than rated
exhaust flow, into the exhaust port on the bottom of the unit.
CAUTION
Installation, commissioning, disassembling as well as repair and
maintenance must only be carried out by qualified specialized
personnel with expertise and experience on pneumatic technology
and in case of electrical devices also electrical technology.
WARNINGS
1. These products are intended for use in industrial compressed air
systems only. Do not use these products where pressures and
temperatures can exceed those listed under Technical Data.
2. Before using these products with fluids other than air, non-
industrial applications or for life-support systems, consult Norgren.
08/20
IM-8.200.616

Advertisement

loading

Summary of Contents for Norgren 82 Series

  • Page 1 GI-5 For ISO G threads do not install fittings that are longer https:/ /www.norgren.com/excelon-plus than 13mm for 84 Series and 10mm for 82 Series GI-6 For Soft Start Valves install only into applications where the downstream pressure can build up TECHNICAL DATA during the initial safe pressure build up stage.
  • Page 2 Excelon Plus 3/2 VALVES ® Air Preparation Range 3/2 Soft Start Dump Valves 3/2 Control Valves Installation and Maintenance Instructions Warning! ISO G thread depth Exceeding these ISO G thread depths can result in malfunction of the unit: Series 84: 3/8”, ½”, ¾” – max. fitting insertion 13mm Series 82: ¼”, 3/8”...