ADDITIONAL SETTINGS

To make the DSES system safer, an additional (and optional) setting is available.
It can be enabled (and disabled) by your INFACO dealer and, when enabled, prevents the
device from being used:
- without a glove being connected to the DSES system
- with the standard cable (non DSES)
- with a DSES cable that has been detected as
being defective
In all three cases, the power supply LED
is red and the secateur will not operate.
19