Frequency Characteristic Check - Sony WRR-862A Service Manual

Uhf synthesized dual diversity tuner
Hide thumbs Also See for WRR-862A:
Table of Contents

Advertisement

(7) Change the MODULATION (modulation frequency) of
the signal generator as shown below.
MODULATION (modulation frequency) : 10 kHz
(Note : 10 kHz modulation frequency must be set by
using the function generator.)
Check that the distortion ratio is less than 8 %.
(8) Set the channel setting (Tuner 1) and FREQUENCY
(carrier frequency) of the signal generator as shown 1
and 2 below.
Perform the procedures (1) to (7) above, for each chan-
nel setting (1 and 2).
1 Channel setting :
Same as procedure (15) section of "3-2-5. S/N
Checking".
2 Channel setting :
Same as procedure (15) section of "3-2-5. S/N
Checking".
(9) Connect the signal generator to ANT b connector.
(10)Perform the procedures (5) to (8).
Step 2. Tuner 2 Checking
(1) Set the CONTROL switch (S1601) to "2".
(2) Connect the audio analyzer to the OUTPUT 2 connec-
tor via the MIC amp.
(3) Connect the signal generator to the ANT a connector.
(4) Set the channel setting as follows;
. Tuner 2 channel setting
Same as "1. Switch and Control Initial Setting" on
page 3-2.
n
Set the Tuner 1 to channel setting different from the
above Tuner 2 channel setting.
(5) Perform the checking from the procedures (5) to (10) in
"Step 1. Tuner 1 checking".
When performing the above described checking change
the following detail as shown below.
OUTPUT 1 → OUTPUT 2
→ Tuner 2
Tuner 1
WRR-862A/862B

3-2-7. Frequency Characteristic Check

n
Perform this adjustment/check with the case (upper) , parti-
tion and battery case installed.
(Do under the regular use condition).
Equipment and Tools
Same as "3-2-5. S/N Checking".
Connection
Same as "3-2-5. S/N Checking".
Switch and Control Setting
Same as "1. Switch and Control Initial Setting" on page 3-2
expect the following setting.
SQUELCH switch : ON
(Set the RF squelch level to "10" )
Procedure
Step 1. Tuner 1 Checking
(1) Set the CONTROL switch (S1601) to "1".
(2) Set the channel setting as follows;
. Tuner 1 channel setting
Same as "1. Switch and Control Initial Setting" on
page 3-2.
n
Set the Tuner 2 to channel setting different from the
above Tuner 1 channel setting.
(3) Connect the audio analyzer to the OUTPUT 1 connec-
tor via MIC amp.
(4) Connect the signal generator to the ANT a connector.
(5) Set the signal generator as follows:
Signal generator setting
FREQUENCY(Carrier frequency):
CE21 model : 482.000 MHz
CE33 model : 578.000 MHz
CE62 model : 810.000 MHz
CE67 model : 850.000 MHz
U1416 model : 482.125 MHz
U3032 model : 578.125 MHz
U4244 model : 650.125 MHz
U6264 model : 770.125 MHz
U6668 model : 794.125 MHz
AU66 model : 799.250 MHz
RF OUTPUT (Output level) : 60 dBuV
MODULATION (Modulation frequency) : 1 kHz
DEVIATION (Frequency deviation) : ± 5 kHz
EMF
(= _53 dBm)
3-11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wrr-862b

Table of Contents