2. Adjustment Location
. Remove the case (upper).
OUTPUT1
ANT a
(BAL)
SQUELCH
(S1602)
LCD
(Tuner 1)
CONTROL
(S1601)
POWER
(S1701)
AU-276/285 board
(B side)
. Remove the case (upper) and partition.
RV611
1 1
RV601
RX-60/74 board (B side)
WRR-862A/862B
OUTPUT2
(BAL)
ANT b
MONITOR
RV1211
MONITOR
1
(S1201)
1
LCD
CT1401
CL1351
(Tuner 2)
1
1
RV711
1 1
RV701

3-2-1. Current Consumption Check

Equipment and Tools
DC power supply
DC output voltage : +1.5 Vdc ± 0.1 V
DC ammeter
DC volt meter (or Digital multimeter)
Connector 4P (Part No. 1-566-425-11)
Switch and Control Setting
Same as "1. Switch and Control Initial Setting" on page 3-2.
Procedure
(1) Remove the case (upper) from the WRR-862A/862B
unit. (For removal, refer to the Section 2.)
(2) Current Consumption Check during Battery Operation
1. Connect a DC power supply (+6 Vdc ± 0.1 V) as
shown in the figure below.
1
1
_
+
2. Check the level on the DC ammeter.
DC ammeter indication level
(under no-RF signal input and SQUELCH
OFF mode) : 220 mA or less
(3) Current Consumption Check during External Power
Supply Operation
1. Connect a DC power supply (+12 Vdc ± 0.1 V) as
shown in the figure below.
DC power
DC
ammeter
supply
+ _
+
_
+12.0 ± 0.1V
Pin No.4
To DC
(+)
POWER
Pin No.1
(_)
SUPPLY
2. Check the level on the DC ammeter.
DC ammeter indication level
(under no-RF signal input and SQUELCH
OFF mode) : 125 mA or less
DC
DC power
ammeter
supply
_ +
+
_
+6.0 ± 0.1V
1
1
+
_
DC 12V IN
4P connector
4
1
3
2
Bottom View