Switching Off - Beretta Quadra Green 25 C.S.I. Installation And User Manual

Hide thumbs Also See for Quadra Green 25 C.S.I.:
Table of Contents

Advertisement

Available languages

Available languages

QUADRA GREEN C.S.I.
Adjusting heating water temperature with an external probe connected
When an external probe is connected, the value of the delivery temperature
is automatically chosen by the system which rapidly adjusts ambient tem-
perature to the changes in external temperature.
To increase or decrease the temperature with respect to the value automa-
tically calculated by the electronic board, turn the heating water selector
clockwise to increase and anticlockwise to decrease.
Adjustment settings range from comfort levels - 5 to + 5 which are indicated
on the digital display when the knob is turned.
Summer mode: turning the selector to the summer mode symbol
28) activates the traditional domestic hot water only function.
If there is a domestic hot water request, the boiler switches on and the
boiler status indicator LED lights up with a fixed green light. The digital
monitor indicates the domestic hot water temperature, the icon to indicate
the hot water supply and the flame icon (fig. 30).
Pre-heating (faster hot water): turning the domestic hot water tempera-
ture adjustment knob to the
function. Bring the domestic hot water temperature adjustment knob back
to the required position.
This function keeps the water in the domestic hot water exchanger hot, to
reduce standby times when a request is made.
When the pre-heating function is enabled, the yellow LED next to the
symbol is lit.
The monitor indicates the delivery temperature of the heating water or the
domestic hot water, according to the current request.
During burner ignition following a pre-heating request, the monitor indicates
the
symbol.
To deactivate the pre-heating function, rotate the domestic hot water tem-
perature adjustment knob back to the
switch off. Bring the domestic hot water temperature adjustment knob back
to the required position.
This function cannot be activated when the boiler is OFF: function selector
to
(OFF) (fig.32).
Adjustment of domestic hot water temperature
To adjust the domestic hot water temperature (bathrooms, shower, kitchen,
etc.), turn the knob with the
the temperature and anticlockwise to reduce it. On the control panel, the
green LED flashes ON for 0.5 seconds then OFF for 3.5 seconds.
The boiler is standby status until, after a heat request, the burner switch-
es on and the indicator LED turns fixed green to indicate flame presence.
The boiler continues to operate until the temperatures set on the boiler are
reached, or the heat request is met; after which it goes back on standby.
If the red LED indicator near the
lights up, this means the boiler is in temporary shutdown status (see the
chapter on "Light signals and faults").
The digital monitor indicates the fault code detected (fig. 34).
4a LIGHT SIGNALS AND FAULTS
The operating status of the boiler is shown on the digital display, below is a
list of the types of displays.
BOILER STATUS
Off status (OFF)
Stand-by
ACF alarm lockout module
ACF electronics fault alarm
Limit thermostat alarm
Tacho fan alarm
Water pressure switch alarm
NTC domestic water fault
NTC heating outlet fault
Heating outlet probe overtemperature
Outlet/return line probe differential alarm
NTC heating return line fault
Heating return line probe overtemperature
Outlet/return line probe differential alarm
14
symbol (fig. 31) activates the pre-heating
symbol. The yellow LED will
symbol (fig. 28) rotate clockwise to increase
symbol (fig. 34) on the control panel
DISPLAY
OFF
-
A01
A02
A03
A04
A06
A07
A08
Automatic Temperature Control System function (S.A.R.A.) fig. 35
Setting the heating water temperature selector to the area indicated, ac-
tivates the automatic temperature control system (frequency 0.1 sec. on;
then 0.1 sec. off; for 0.5 seconds): according to the temperature set on the
room thermostat and the time taken to reach it, the boiler varies automati-
cally the heating water temperature reducing the operating time, allowing
greater ease of operation and energy saving. On the control panel, the
green LED flashes ON for 0.5 seconds, OFF for 3.5 seconds.
Reset function
(fig.
To restore operation, set the function selector to
seconds then set it to the required position, checking that the red indicator
light is OFF. At this point the boiler will automatically start and the red lamp
switches on in green.
NOTE: If the attempt to reset the appliance does not activate operation,
contact the Technical Assistance Service.
3a SWITCHING OFF
Temporary switch-off
In case of absence for short periods of time, set the mode selector to
(OFF) (fig. 32).
In this way (leaving the electricity and fuel supplies enabled), the boiler is
protected by:
Anti-frost device: when the temperature of the water in the boiler falls
below 5°C, the circulator and, if necessary, the burner are activated at mini-
mum output levels to bring the water temperature back to the values for
safety (35°C). During the anti-frost cycle, the symbol
on the digital monitor.
Circulator anti-blocking function: an operation cycle is activated every
24 hours.
Switching off for long periods
In case of absence for long periods of time, set the mode selector to
(OFF) (fig. 32). Turn the main system switch OFF. Close the fuel and water
taps of the heating and domestic hot water system. In this case, anti-frost
device is deactivated: drain the systems, in case of risk of frost.
RED LED
YELLOW LED
on
flashing 0.5 on/
0.5 off
on
on
flashing 0.5 on/
0.5 off
on
on
(OFF) (fig. 32), wait 5-6
(fig. 36) appears
TYPES OF
GREEN LED
ALARMS
flashing 0.5 on/
None
3.5 off
flashing 0.5 on/
Signal
3.5 off
Definitive lockout
Definitive lockout
Definitive lockout
on
Definitive lockout
flashing 0.5 on/
Signal
0.5 off
Temporary stop
Temporary then
definitive
Definitive lockout
Temporary stop
Temporary then
definitive
Definitive lockout

Hide quick links: