Download Print this page
FAAC XPB34-1 Manual
FAAC XPB34-1 Manual

FAAC XPB34-1 Manual

Safety sensors for automatic swing doors

Advertisement

Quick Links

LED-SIGNALS
The RED or GREEN
Bad adjustment
LED is ON sporadicly.
The RED or
Bad adjustment of the
GREEN LED is ON
uncovered zone.
permanently.
The sensor does not
The monitoring is activated,
react, but a calibration
but the test input is not
can be launched.
powered.
The sensor encounters
The ORANGE LED is
a memory problem.
on permanently.
DIP-switch setting
The ORANGE LED
fl ashes quickly.
awaiting confi rmation.
The ORANGE LED
The sensor signals an
internal fault.
fl ashes 1 x
1
every 3 seconds.
Power supply is out of limit.
The ORANGE LED
fl ashes 2 x
2
every 3 seconds.
Communication error
The ORANGE LED
between modules.
fl ashes 3 x
3
every 3 seconds.
The sensor receives
The ORANGE LED
fl ashes 4 x
not enough IR-energy.
4
every 3 seconds.
The sensor receives too
The ORANGE LED
fl ashes 5 x
much IR-energy.
5
every 3 seconds.
Calibration error
The ORANGE LED
The sensor is disturbed by
lamps or another sensor.
fl ickers.
SAFETY INSTRUCTIONS
The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system in compliance with applicable
national and international regulations and standards on door safety and if applicable, the machinery directive 2006/42/EC.
Only trained and qualifi ed personnel may install and setup the sensor.
The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel.
Avoid touching any electronic and optical components.
FAAC S.p.A . - Via Calari, 10 40069 Zola Predosa - Italia - tel. +39 051 61724 - fax. +39 051 758518 - www.faacgroup.com
BEA hereby declares that the FAAC XPB34-1/70-1/90-1/90-2 ON is in conformity with the basic requirements and the other
relevant provisions of the directives 2004/108/EC and 2006/42/EC.
Notifi ed Body for EC inspection: 0044 - TÜV NORD CERT GmbH, Langemarckstr. 20, D-45141 Essen
Angleur, May 2013
Pierre Gardier, Authorized representative
Only for EC countries: According to the European Guideline 2002/96/EC for Waste Electrical and Electronic Equipment (WEEE)
Manufactured by: BEA SA - LIEGE Science Park - Allée des Noisetiers 5 - 4031 Angleur - Belgium - T +32 4 3616565 - F +32 4 3612858 - info@bea.be - www.bea.be
1
Check if the DIP-switch 4 is ON (uncovered zone).
2
Launch a calibration.
1
Check if the DIP-switch 4 is ON (uncovered zone).
2
Launch a calibration.
Chech wiring.
1
- Door control with test:
Connect RED and BLUE wires to test output.
- Door control without test:
Connect RED to 0 V and BLUE to +12 V - 30 V DC.
1
Send the sensor back for a technical check-up.
Corfi rm the DIP-switch setting:
1
long push on the push button.
1
Cut and restore power supply.
If orange LED fl ashes again, replace sensor.
2
1
Check power supply (tension, capacity).
2
Reduce the cable length or change cable.
1
Check wiring between modules.
Launch a module count: long push on push button
2
of MASTER.
1
Launch a new calibration.
2
Step out of the detection fi eld.
3
Change angle of spots.
Switch off background (DIP 3: OFF).
4
1
Launch a new calibration.
1
Check mounting height.
2
Change position of calibration screw.
Launch a new calibration.
3
1
Select a different frequecy for each module (DIP 2).
Launch a new calibration.
Please keep for further use
Designed for colour printing
Other use of the device is outside the permitted purpose
and can not be guaranteed by the manufacturer.
The manufacturer cannot be held responsible for incorrect
installations or inappropriate adjustments of the sensor.
DESCRIPTION
1
2
3
4
5
1.
6
2.
3.
4.
5.
6.
TECHNICAL SPECIFICATIONS
Technology:
active infrared with background suppression
Detection fi eld:
400 mm (W) x 70 mm (D) (at 2 m mounting height; 4 spots active)
Mounting height:
1.1 m to 3 m (according to fl oor refl ectivity)
Reaction time:
64 ms (typ)
Max. presence time:
infi nite
Supply voltage:
12 V - 24 V AC +/-10% ; 12 V - 30 V DC -5%/+10%
(to be operated from SELV compatible power supplies only)
Max current consumption:
110 mA @ 24 V AC/ 70 mA @ 24 V DC; 190 mA @ 12 V AC/ 145 mA @ 12 V DC (MASTER)
85 mA @ 24 V AC/ 60 mA @ 24 V DC; 180 mA @ 12 V AC/ 113 mA @ 12 V DC (other modules)
Output:
2 relays (free of potential contact)
Max. contact voltage
42 V AC/DC
Max. contact current
1 A (resistive)
Max. switching power
30 W (DC) / 60 VA (AC)
Input:
1 optocoupler (free of potential contact)
Max. contact voltage:
30 V
Voltage threshold:
high: >10 V DC; low: <1 V DC
Max. number of modules:
4 (up to 6 if 24 V DC)
Refl ectivity:
min. 5% at IR-wavelength of 850 nm
Degree of protection:
IP53
Temperature range:
-25 °C to +55 °C; 0-95% relative humidity, non condensing
Expected lifetime:
5 years
Norm conformity:
EMC 2004/108/EC; MD 2006/42/EC; EN 12978
EN ISO 13849-1:2008 Performance Level «c» CAT. 2
(under the condition that the door control system monitors the sensor at least once per door cycle)
XPB34-1/70-1 ON
XPB90-1/90-2 ON
Safety sensors
for automatic swing doors
profi le
7.
end cap
supporting clip
8.
clip with angle adjustment screw
main connector
9.
transmitter (TX)
DIP-switch
10.
push button
calibration screw
11.
front face
receiver
Specifi cations are subject to changes without prior notice.
All values measured in optimal conditions.
7
8
9
10
11

Advertisement

loading
Need help?

Need help?

Do you have a question about the XPB34-1 and is the answer not in the manual?

Questions and answers

Summary of Contents for FAAC XPB34-1

  • Page 1 Temperature range: -25 °C to +55 °C; 0-95% relative humidity, non condensing FAAC S.p.A . - Via Calari, 10 40069 Zola Predosa - Italia - tel. +39 051 61724 - fax. +39 051 758518 - www.faacgroup.com Expected lifetime: 5 years...
  • Page 2 MOUNTING THE PROFILE SETTINGS MOUNTING FREQUENCY BACKGROUND UNCOVERED Mount the profi les as close as possible ZONE SIDE to the closing edge. Leave 2 cm for the black end caps. RELAY 1 FREQ A 35 cm* OPENING SIDE Take the position of the white clips 2 cm into account before drilling and RELAY 2...

This manual is also suitable for:

Xpb90-1Xpb90-2Xpb70-1785019785021785032