FAAC XMA User Manual
FAAC XMA User Manual

FAAC XMA User Manual

Combined bidirectional opening and safety sensor without any monitoring function

Advertisement

Quick Links

1

Description

Radar motion sensor
Radar Antenna
Radar tilt angle indication
2

Symbols and LED

LED turns on
LED display during normal function
GREEN LED
RED LED
ORANGE LED
3

Installation

1
Tips
Avoid touching electronical
parts!
Avoid vibrations!!!
COMBINED BIDIRECTIONAL OPENING AND SAFETY SENSOR
45°
30°
15°
LED flashing slowly
LED flashing quickly
Motion detection
Presence detection
See chapter 4: Troubleshooting
Avoid touching optical parts!
Do not cover the sensor!
WITHOUT ANY MONITORING FUNCTION
Motion detection
Make sure the operator
cover is fixed properly and
electrically earthed.
Avoid moving objects in
proximity to the sensor!
fluorescent lighting in proximity
USER'S GUIDE
Cover
Push-Buttons
IR-Presence sensor
IR-Prism
Main Connector
IR curtain adjustment screw
Presence detection
Avoid discharge lamps and
of the detection field!
XMA
Tip
Avoid highly reflective
objects in the infrared field!
1/4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the XMA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for FAAC XMA

  • Page 1 USER'S GUIDE COMBINED BIDIRECTIONAL OPENING AND SAFETY SENSOR WITHOUT ANY MONITORING FUNCTION Description Cover Push-Buttons Radar motion sensor IR-Presence sensor Radar Antenna IR-Prism Radar tilt angle indication 45° Main Connector 30° 15° IR curtain adjustment screw Symbols and LED LED turns on LED flashing slowly LED flashing quickly Motion detection...
  • Page 2 Mounting the sensor Mount the sensor at a maximum height of 5cm from the bottom line Use the mounting template to drill holes and position the sensor. of the door operator. Wiring the sensor To ensure good water protection, place the cable as shown above. Radar motion sensing field: width Sensitivity = 9 Sensitivity = 9...
  • Page 3 Setting the radar sensitivity by push button Each short press on the right button increases the size of the radar sensing field. Each short press on the left button decreases the size of the radar sensing field. IR presence sensing field : width Make sure to introduce the front 2 curtains of 12 overlapping spots 2 curtains of 24 overlapping spots...
  • Page 4 Sensing field dimensions given at 2.2m mounting height. Specifications are subject to changes without prior notice. Accessories (sold individually) FAAC S.p.A . - Via Benini, 1 40069 Zola Predosa - Italia - tel. +39 051 61724 - fax. +39 051 758518 - www.faacgroup.com...

Table of Contents