Electrical Installation - Asko T712C Use And Care Manual

Asko t712c: user guide
Table of Contents

Advertisement

Electrical installation

The machine must only be connected to an
earthed wall socket.
Caution:
If this appliance is supplied from a cord
extension set or an electrical portable outlet
device, the cord extension set or electrical
portable outlet device must be positioned
so that it is not subjected to splashing or
ingress of moisture.
Connection on delivery
The machine is supplied as single-phase,
230V, heat output 1950W (see type plate)
and has a 10A fuse. Any earth fault fuses
must be type A.
Alternative connection
It is possible to switch over from 10A
(heat output 1950W) to 16A (heat output
2500W). Switching must be carried out as
follows:
1. Shut off the power.
2. Press and hold the Start/Stop button, and
switch on the power.
3. Release the Start/Stop button once the
programme indicator lights up.
4. Press the Start/Stop button 5 times
(within 10 seconds).
5. Adjust the programme selector so that
the Extra Dry light comes on (10 o'clock).
6. Press the Start/Stop button to store the
setting.
If you want to reset the machine to a 10A
connection:
1. Repeat steps 1-4.
2. In step 5, adjust the programme selector
so that the Extra Dry light goes out.
3. Press the Start/Stop button to store the
setting.
The machine now has a 10A connection.