  • Page 1 SDS131T Instant Match Transformer Quick Connect Guide WITH...
  • Page 2 Waste Pipe Wireless System Registration Important Information WARNING Please read the following information before setting up a wireless connection between the Whale Instant ® ® Match wireless transformer and Mira Advance Flex Extra Wireless (J97P) • The electrical wiring must conform to EU wiring regulations BS7671:2008 Part 7 (17th Edition).
  • Page 3 2. Transformer set up • Switch the mains electric supply to the transformer ON. The light on the transformer will now flash red to indicate that a wireless connection has not yet been established. • Press and HOLD the yellow test button on the transformer until the light flashes red and green to indicate that the transformer is now in pairing mode.
  • Page 4 Some service work that may need to be carried out on the Mira Advance shower e.g. the renewal of the control PCB board may require the wireless connection ® between the shower and Whale Instant Match transformer to be terminated and paired again once the work has been completed. To unpair the transformer from the shower, please follow these steps.
  • Page 5 3. De-registration sequence • Move jumper from position 7 to any other position. • Power ON the transformer. • Press and Hold yellow test button for 5 seconds to de-register. • Power OFF the transformer. • Move the jumper to position 7 •...
  • Page 6 Plumbing of the Waste Pipe Shower Hardwired Connections Cont'd Mira ® Advance Flex Extra wireless (J97P) ® Wired Connections to the WHALE INSTANT MATCH Transformer Flex Extra J09N Please ensure that the L K2 Jumper jumper on the Mira J97P...
  • Page 7 Plumbing of the Waste Pipe Shower Hardwired Connections ® Triton Safeguard + Omnicare Design, Omnicare Style, T150Z+ Wired Connections to the Whale ® Instant Match Transformer Transformer Whale Transformer Settings Blue Jumper - Sensor Position 4 Grey Jumper - Over run 10 Seconds Red Jumper - Pipe inlet 15mm ®...
  • Page 8 Waste Pipe ® Whale Instant Match Transformer Flow Sensor Connections ® Sika Sensor Connection Please see below for jumper and wiring connections. ® Whale Transformer Settings ® Sika Sensor Please ensure that water flow Blue Jumper - Sensor Position 2...
  • Page 9 (Venturi) Connection ® When connecting to the Grundfos Venturi sensor it is important to connect an earth wire from the Venturi sensor to the signal ® earth connection on Whale transformer (shown below). ® Whale Transformer Settings Venturi sensor Please ensure that water flow...
  • Page 10 In a situation where a Bluetooth wireless technology or hardwired connection with the shower cannot be established, or a suitable flow sensor has not been fitted, the Whale SDS236T Instant Match transformer can be used with an AK1568 flow switch to activate the pump.
  • Page 11 Red Jumper - Pipe inlet 22mm ©Copyright Whale 2019 - All rights reserved. Reproduction in whole or in part without permission is prohibited. WHALE® and WHALE INSTANT MATCH® are registered trademarks of Munster Simms Engineering Limited, Bangor, Northern Ireland trading as Whale.
  • Page 12 0345 9090 912 drainagesupport@whalepumps.com www.whalepumps.com Whale, 2 Enterprise Road, Bangor, Co. Down, @Whalecare BT19 7TA, N.Ireland Ref. 182.605_v3_0619...