ETC EBDK-SWITCH Setup Manual page 2

Reset switch

Advertisement

ETC Setup Guide
EBDK Reset Switch
Install EBDK Reset Switch for an EBDK
1:
Install the back box according to standard electrical practices. The back box should be installed flush
and square for best installation results.
2:
Pull two 1.5 mm
single-gang back box.
Note:
3:
Strip 9-10 mm (3/8 in) from the ends of the 1.5 mm
4:
Locate the WAGO cage clamp connectors in the packaging. WAGO connectors are provided as a
means to connect the installed control wire to the harness wires provided on the EBDK-SWITCH.
5:
Open two terminal levers on each WAGO connector and insert the 1.5 mm
control wire for V out and the Input switch wire into terminals and close the levers. See the image
below for topology.
Note:
6:
Install the switch into the back box and secure using the two screws provided.
Single
switch
Two
switches
in series
EBDK Reset Switch
2
(16 AWG) wires through grounded metal conduit from the EBDK to the installed
You can wire up to two EBDK Reset Switches in series within a maximum distance of
152 m (500 ft) between the EBDK and the last EBDK-SWITCH in the line.
You can install up to two EBDK Reset Switches in series per EBDK (see image below).
EBDK
EBDK
2
(16 AWG) installed control wires.
EBDK Reset Switch
EBDK Reset Switch
Page 2 of 3
2
(16 AWG) installed
EBDK Reset Switch