Replacement And Repair; Revision Summary - TE Connectivity 354711-1 Instruction Sheet

Modular plug single terminators

Advertisement

2. .Lubricate the ram if necessary with a THIN coat
of high-pressure grease. DO NOT lubricate
excessively. Store in a clean, dry area.
CAUTION
Be sure to keep the termination areas of the stuffers and
nest areas especially clean. DO NOT oil or grease the
termination areas of the stuffers.
8.2. Periodic Inspection
Personnel responsible for the terminator should
perform regular inspections, record the results, and
keep a record of inspections with the terminator.
It is recommended that inspection procedures be
performed at least once a month. Work environment,
company standards, or amount of terminator use may
dictate more frequent inspections.
CAUTION
Failure to perform periodic inspection and daily
maintenance can cause the terminator to make
defective terminations leading to discontinuities on
individual wire circuits.

9. REPLACEMENT AND REPAIR

Order replacement parts through your representative,
or call 1-800-526-5142, or send a facsimile of your
purchase order to 717-986-7605, or write to:
DIM. A
MODULAR
(Wire Insertion
PLUG TYPE
Depth)
Standard and
0.00-0.64
Small Conductor
[.000-.025]
High
0.00-0.25
Performance
[.000-.10]
(Category 5)
Rev G
CUSTOMER SERVICE (038-035)
TYCO ELECTRONICS CORPORATION
PO BOX 3608
HARRISBURG PA 17105-3608
For customer repair service, call 1-800-526-5136.
10. STORAGE
If the tool is not used, it must be stored by taking the
following precautions:
1. Store the tool indoors.
2. Grease unpainted parts.
3. Protect this tool from knocks or stresses.
4. Protect this tool from high levels of humidity and
from big temperature changes.
5. Prevent the tool from coming into contact with
corrosive substances.
11. DECOMMISSIONING
In compliance with the regulations in force in the
country where the tool is used, the user must make
sure that waste produced during operation is correctly
disposed of. Disposal of lubricants and parts removed
must be carried out in compliance with the standards
in force in the country where the tool is used.

12. REVISION SUMMARY

Since the previous release of this document , the
document format was revised and the software was
translated.
Contact Crimp Height
6.02 ± 0.13 [.237 ± .005]
End of Wire Circuit
"A"
Figure 5
Contact
End of Conductor
408-9919
7 of 7