4. INSTALLATION

The terminator requires a regulated air supply
pressure range of 551 kPa [80 psi] to 689 kPa [100
psi] at .35 liter/sec [.75 scfm] to properly terminate all
modular plugs. A .125 inch NPT fitting is included on
the end of the terminator supply line to be installed into
the air supply.
Select an appropriate location for the machine. The
location should be well lighted, and should have
convenient and adequate air and power supplies.
1. Secure the machine to the bench with two M4 or
8-32 bolts or lag screws.
2. Blow air through the air hose to remove any
foreign particles before attaching supply hose to the
back of the machine.
Filter and
Moisture Separator
Air Flow
Drain Regularly
Rev G
Quick Disconnect
Out
Pneumatic Schematic
Figure 2
3. Install air line filter, air pressure regulator, and
lubricator (supplied by the customer) between the
air supply and hose, as shown in Figure 3. The
assembly must be as close as possible to the
machine. Fill the air line lubricator with a good grade
air line lubricant (as recommended by the filter
manufacturer). When machine is not in use, the air
supply should be turned "OFF."
4. It is also recommended that quick-disconnect
fittings are used to connect the tool to the air supply.
If not using quick-disconnect fittings, provide a
pneumatic lock-out on the air line that bleeds air
after it is turned off.
Regulator
Check Air Pressure Regularly
551kPa [80 psi], Min., 690 kPa [100psi], Max.)
Figure 3
408-9919
Air Cylinder
Lubricator
To Tool
Check Oil Level Regularly
(Adjust to Very Fine Mist)
4 of 7