About this guide

This guide provides instructions to install the Nortel Networks* BayStack* 380 10/100/1000
switch on a table or in an equipment rack. For more detailed information about the switch, refer to
Using the BayStack 380 10/100/1000 Switch (part number 212859-A).
This guide includes information about the following topics:
Environmental requirements for the installation site (next)
Installing the switch on a table
Network connection requirements
Connecting AC power
Descriptions of LEDs
Initial switch setup

Before you begin

Make sure the area where you will install and use the BayStack 380 Switch meets these
environmental requirements:
Ambient temperature between 41° and 104° F (5° and 40° C)
Relative humidity between 5% and 85% noncondensing
No nearby heat sources such as hot air vents or direct sunlight
No nearby sources of severe electromagnetic noise
No excessive dust
Adequate power source within six feet; one 15-Amp circuit required for each power supply
At least 2 inches (5.08 cm) on each side of the switch unit for ventilation.
Adequate space at the front and rear of the switch for access to cables.
If you are installing a single BayStack 380 Switch on a table or shelf, make sure the surface will
support at least 5 to 10 pounds.
Note: The direction of air flow in the BayStack 380 switch is from left to right.
(page
5) or in a rack
(page
(page
9)
(page
9)
(page
11)
(page
6)
7)
Installing the BayStack 380 10/100/1000 Switch