Required clearance

The following clearance is required for sufficient self-ventilation around the device:
At least 10 mm to the right and left of the mounting cutout (in x direction)
At least 10 m above and below the mounting cutout (in y direction)
At least 10 mm behind the rear panel of the device (in z direction).
The figure below shows the required clearances when the device is installed in landscape and portrait format:
Clearance for mounting in landscape format
Clearance for mounting in portrait format
x
At least 10 mm distance
y
At least 10 mm distance
z
At least 10 mm distance
Note
Ensure that the permitted ambient temperature is not exceeded when mounting the device in a cabinet and especially in a
closed enclosure.

Mounting the device

Installation guidelines
NOTICE
Damage to the device due to the open front
The frameless front does not have a protective enclosure. Electrostatic-sensitive components are destroyed on contact with
wires. The front can warp when shear forces are applied. This can result in damage to the machine or system.
Observe the safety information on ESD guidelines.
Do not expose the front to mechanical stress, e.g. during installation.
Ensure adequate sealing during installation.
Higher degrees of protection of the device front can only be guaranteed if the mounting seal is intact and lies flush
against the mounting cut-out.
To guarantee a higher degree of protection, you need to take suitable measures yourself. With correct installation, IP65
can be reached.
Observe the minimum thickness of the enclosure (material thickness): Height of threaded sleeve = 5.5 mm.
Observe the length of the M3 screws: Maximum screw-in depth into threaded sleeve = 5 mm.
Note CAx data
The CAx data for electrical planning (circuit diagrams, data sheets, ePlan macros), for example, are available from the
underlying standard devices. A description of how to obtain this data can be found on the Internet: CAx Download
(https://support.industry.siemens.com/cs/us/en/view/89671877)
20
SIMATIC IFP2200/2400 ITC2200/2400 frameless
A5E48015893-AC, 03/2021

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic ifp2400Simatic itc2200Simatic itc2400

Table of Contents