AS-i Safety Relay Output Module with Diagnostic Slave
1 EDM- and 2/1 safety inputs
Safety
3.
Safety
This chapter contains user safety information.
Warning!
Please read this chapter carefully before using the AS-i Safety Relay Output in combi-
nation with other machine safeguarding components on protected machinery.
3.1
Experienced staff
The AS-i Safety Relay Output Module with Diagnostic Slave must only be in-
stalled, operated, and maintained by qualified staff.
Qualified is a person who
•
has a suitable technical education
•
has been instructed in operating the machinery and has been informed about
the valid safety guidelines by the machinery operator
•
has access to the user manual.
3.2
Application area of the device
The module BWU2236 is a decentralized output-module that safely controls ac-
tuators on the AS-i Safety at Work (SaW) safety bus system.
In this set-up, a Safety Monitor or a Gateway with integrated Safety Monitor, re-
spectively, controls the BWU2236.
A special characteristic of this module is its three different kinds of AS-i address-
es:
•
safety output
BWU2236 listens to the communication on the safe address and switches
based on these data.
•
safety input slave
One safety input slave which monitors the two contacts S1 and S2.
•
diagnostic slave
The standard AS-i slave (AB slave) is used for diagnostic purposes and for
switching under normal operating conditions.
Attention!
For protective operation of the module the switches must be in the ON/RUN position.
All SaW output modules with the same safe AS-I address switch at the same
time.
The module BWU2236
EN 13 849, performance level "e".
Subject to technical modififications; no responsibility is accepted for the accuracy of this information
8
Internet: www.bihl-wiedemann.de • Flosswoerthstr. 41 • D-68199 Mannheim
is certified according to EN 62 061, SIL 3, and
phone: +49 621 33 996-0 • fax: +49 621 3 39 22 399
© Bihl+Wiedemann GmbH