  • Page 1 SuperK VARIA Variable Bandpass Filter PRODUCT GUIDE Item 800-615-01...
  • Page 2 PRODUCT GUIDE This guide includes the following NKT Photonics products: SuperK VARIA Variable Bandpass Filter A301-100-000 SuperK VARIA Product Guide Release 1.1 01-2021 W-10456...
  • Page 3: Guide Overview

    A USB memory stick is included. It contains documentation for all NKT Photonics products including this accessory. Terminology The guide may refer to the SuperK VARIA as the VARIA, device or accessory. Target Audience This guide is for technical personnel involved in the selection, planning and deployment of lasers and photonic equipment in laboratory and industrial settings.
  • Page 4 Added information Lasers with their accessories are highly dangerous devices that can cause and Safety Notices serious injury and property damage. This guide use the following symbols to either highlight important safety information or provide further information in relation to a specific topic. Note: Highlights additional information related to the associated topic and/or pro- vides links or the name of the NKTP guides describing the additional information.
  • Page 5: Table Of Contents

    Output ........................13 Interlock ........................13 Shutters ........................13 Top panel ........................14 Optical apertures ....................16 Electrical Interfaces ....................17 SuperK VARIA Control ..................... 18 Software Description ..................18 Status LEDs ......................... 18 Chassis labels ......................20 2 Installation ...........................23 Installation process .....................23 General ........................23 Optical Connections ....................
  • Page 6 Device Selector ......................30 Address selector ....................30 Status Panel ........................ 31 Status Indicators ....................31 System Info ......................32 Output power monitor ..................32 Emission button ....................32 Control settings ......................33 Reset ........................33 View ........................33 Bandwidth restrictions ..................34 Control panel ......................
  • Page 7: Tables

    TABLES Table 1: Status LEDs......................19 Table 2: Chassis labels ....................... 20 Table 3: Interfaces ........................37 Table 4: Mechanical dimensions ..................37 Table 5: Operating and storage environment ..............37 Table 6: Safety and regulatory compliances ..............37...
  • Page 9: Figures

    FIGURES Figure 1: SuperK VARIA general view ................13 Figure 2: Auxiliary output – shutter knob set to open ..........14 Figure 3: Top panel ......................15 Figure 4: Optical Interfaces ....................16 Figure 5: Electrical Interfaces and optical input ............17 Figure 6: Status LEDs ......................
  • Page 10 white...
  • Page 11: Procedures

    PROCEDURES Procedure 1: Inserting a SuperK output collimator ............. 24 Procedure 2: Installing CONTROL ..................41...
  • Page 13: Description

    Description The SuperK VARIA is a plug & play filter accessory for the SuperK series of lasers. The VARIA provides a filtered output channel using a variable bandpass filter. The VARIA also includes a secondary output channel which emits the remaining portion of unfiltered light.
  • Page 14: Top Panel

    Features shutters are manually operated by turning the shutter knob between the Open and Closed positions as shown in Figure Figure 2 Auxiliary output – shutter knob set to open Output aperture shutters Open – emission unblocked Closed – emission blocked Caution: When the laser outputs are not in use, NKTP recommends to CLOSE the shutters.
  • Page 15: Figure 3 Top Panel

    Set the shutter to “Closed” to block emission and “Open” to unblock emission from the aperture. Mounting holes The two mounting holes (2) are designed to fasten the SuperK VARIA to either metric or imperial optical tables that have screw holes spaced at either 25 mm or 1” pitch.
  • Page 16: Optical Apertures

    Features Note: You can lock the collimator once it is in the optical input by tightening the collimator locking screw (5). Optical apertures Optical apertures are located on the side panels of the VARIA as shown in and described in the following. Figure 4 Figure 4 Optical Interfaces Optical input aperture –...
  • Page 17: Electrical Interfaces

    This port outputs an electrical signal representing the repetition rate of the laser’s output pulse. The port is optional and only available on custom orders. Contact NKT Photonics sales engineering for further information. External bus input port The bus input port connects accessories in a daisy chain with a SuperK laser.
  • Page 18: Superk Varia Control

    SuperK VARIA Control accessories after all accessories on the External bus daisy chain are configured with a unique address. Bus through output port Connects additional accessories to the External bus in a daisy chain configuration. A bus defeater must be connected to this port if no other accessories are used with the SuperK laser.
  • Page 19: Table 1 Status Leds

    Status LEDs Figure 6 Status LEDs Power Interlock Emission Table 1 Status LEDs LED Name Condition Description Emission ON RED Emission enabled The SuperK laser system emission is ON and class 4 emission is present at the primary and auxiliary optical output ports.
  • Page 20: Chassis Labels

    Chassis labels Chassis labels The SuperK VARIA chassis includes multiple labels that indicate hazards and safety and product information. The labels are located on the panels as described in with the panels shown in Table 2 Figure 7 Figure Table 2 Chassis labels...
  • Page 21: Figure 8 Top Panel Labels

    Chassis labels Figure 8 Top panel labels 3. Class 4 Laser Radiation Warning Laser Aperture Laser Radiation Warning NOTE: Laser apertures are located on the side panel below the label.
  • Page 22 Chassis labels...
  • Page 23: Installation

    Caution: The SuperK VARIA is intended for use with the SuperK Class 4 lasers sys- tems only. Using the SuperK VARIA with a laser source other than a SuperK laser may result in hazardous radiation exposure. Warning: To operate these systems, you must be familiar with laser safety regulations...
  • Page 24: Optical Connections

    Disconnect power from the laser. 2. If not already installed, position the SuperK VARIA at its final operating location and securing it to a suitable mounting surface. 3. Partially insert the laser’s output collimator barrel into the Optical Input...
  • Page 25: Figure 11 Collimator Lock Screw

    Optical Connections 5. Push the collimator into the receptacle until its collar rests against the chassis. As you push it in, the collimator will encounter some resistance, and two distinct clicks as it locks in place. Note: Again, you may need to turn the collar slightly to align the collimator key with the alignment slot.
  • Page 26: Electrical Connections

    Electrical Connections Electrical Connections External bus For basic operation, connect the External bus of the SuperK laser to the Bus Input of the VARIA. To connect the bus: Disconnect power from the laser. Caution: If the laser is powered ON when connecting the external bus cable, DAMAGE can occur to both the laser and the VARIA.
  • Page 27: Adding Additional Accessories

    Electrical Connections Note: If you do not terminate the External bus with an NKT Photonics bus defeat- er, the interlock circuit remains open and laser emission cannot be enabled. Adding additional If any additional accessories are to be connected to the SuperK laser, use an...
  • Page 28 Electrical Connections...
  • Page 29: Control Interface

    Figure 15 shows CONTROL’s main panels and menu; their functions are described in the table below. This chapter only describes CONTROL operations related to the SuperK VARIA, for all other functionality, refer to the specific SuperK documentation. Panel Function...
  • Page 30: Device Selector

    Device Selector Device Selector You can find the list of SuperK nodes that CONTROL is currently communicating with in the Device selector. To manage any device, click on its corresponding icon. When the icon is highlighted blue, it indicates that the Control panel and Status panel are displayed for that device.
  • Page 31: Status Panel

    Status Panel Status Panel The Status Panel for the VARIA provides status indicators, error messages, an emission control button, and a CONTROL settings menu. Figure 19 Status Panel Settings drop-down menu Status indicators System information & error display area Output power monitor readings Emission button and indicator...
  • Page 32: System Info

    Status Panel Interlock Indicates the status of the Interlock circuit and whether emissions can be turned on or not. The indicator will be either: • ON Red – the interlock circuit is open or shorted to ground – No emissions allowed •...
  • Page 33: Control Settings

    Control settings Control settings The CONTROL settings are accessible by clicking the gear icon in the upper right corner of the Status panel. Clicking the gear icon provides access to the View settings menu as shown in Figure Figure 20 CONTROL settings Click the gear icon to access the menu Reset...
  • Page 34: Bandwidth Restrictions

    Control panel Output power monitor – check the box next to “Output power monitor” to toggle ON the display of the gain setting and monitor signal level in the status panel. Figure 22 View settings Check to toggle ON displaying status panel System info and/or System info and/or Output power monitor parameters.
  • Page 35: Using A Bandwidth Less Than 10 Nm

    Control panel • Bandwidth – slider control for the total bandwidth of the filtered output spectrum in nanometers. The bandwidth will be equally distributed on either side of the set center wavelength. Range: 10-100 nm • Start/Stop – you can manual set the lower and upper bandwidth limits using the two start stop slider controls.
  • Page 36: Using A Bandwidth Greater Than 100 Nm

    Control panel “Bandwidth restrictions” settings to change the Bandwidth slider scale to permit the reduced bandwidth as shown in Figure Figure 25 Reduced Bandwidth set to 3.0 nm Using a bandwidth You can increase the bandwidth output from the VARIA to beyond 100 nm. greater than 100 nm Beyond the 100 nm limit, the quality of the output spectrum is diminished.
  • Page 37: A Specifications

    Table 3 Interfaces All Chassis Models DB-15 Female External bus Monitor BNC (Optional - Custom feature, contact NKT Photonics) Table 4 Mechanical dimensions Specification 68 x 272 x 212 mm (2.68 Size (H x W x D) x 10.71 x 8.35 in) Weight 7.9 kg (17.4 lb)
  • Page 38: Figure 27 Mechanical Dimensions

    Figure 27 Mechanical dimensions...
  • Page 39: B Service And Support Information

    The unit is sealed with a label “WARRANTY VOID IF REMOVED”. It is strictly IF REMOVED label prohibited to remove the chassis cover Support Contact Details For technical or general support, NKT Photonics can be contacted for help regarding issues and questions with your accessory. Online Support 1. Go to: Web-page https://www.nktphotonics.com/lasers-fibers/support/technical-support-and-...
  • Page 40: Shipping Address

    Support Contact Details Shipping Address NKT Photonics A/S Blokken 84 DK-3460 Birkerød Denmark...
  • Page 41: C Control Software

    CONTROL Software Installing CONTROL Download the software from: https://www.nktphotonics.com/lasers-fibers/support/software-drivers/ Follow the steps in Procedure Procedure 2 Installing CONTROL Action On the PC, launch the installer package and then click the Installer Run button. The installation wizard appears. Click Next to continue.
  • Page 42 Installing CONTROL Action Accept to use the default installation directory or select another directory by clicking the Browse button. Click Next to continue. Uncheck the components you do not require. By default, all components will be installed. Click Next to continue. Read the End-User License Agreement, and select: “I accept the license.”.
  • Page 43 Installing CONTROL Action The wizard will create a start menu folder with program short-cuts. Use the default name or enter a new name for the folder. Click Next to continue. Check the box to create a desktop shortcut to access Control.
  • Page 44 Installing CONTROL Action Click Install to install NKTP Control software on your PC. Click Cancel if you want to abort the installation. The wizard displays a progress meter for the installation. Note: a normal install should only take a few seconds. Click Next to install the UART drivers for the PC USB port.
  • Page 45 Installing CONTROL Action The drivers will be installed. The Silicon Labs drivers is installed successfully. Click Finish to end the installation wizard. CONTROL is now installed. Check the Run box to launch CONTROL when the Finish button is clicked. Click Finish.
  • Page 46 Installing CONTROL...
  • Page 47 SuperK VARIA Product Guide Release 1.1 01-2021 W-10456...