KeepRite KLP Series Product Data & Installation

KeepRite KLP Series Product Data & Installation

Low profile evaporators

Advertisement

PRODUCT DATA &
INSTALLATION
Bulletin K30-KLPD-PDI-4
Part # 1109283
PRODUCT SUPPORT
web: www.k-rp.com/klp
email: evaps@k-rp.com
call: 1-844-893-3222 x520
CONTENTS
Nomenclature.............................................................................................................................
Features & Options.....................................................................................................................
Selection Data............................................................................................................................
Electrical Data............................................................................................................................
Annual Walk-In Energy Factor (AWEF) Ratings..............................................................................
Dimensional Data.......................................................................................................................
Shipping Weights........................................................................................................................
Recommended Expansion Valve Selections..................................................................................
Defrost Kit and Fuse Package Selections / Details .......................................................................
Installation Instructions..............................................................................................................
Hot Gas Piping Schematics.........................................................................................................
Project Information.....................................................................................................................
"As Built" Service Parts List.........................................................................................................
KLP
Low Profile
Evaporator
Air, Electric, & Hot Gas Defrost
scan:
Electrical Power:
115/1/60, 208-230/1/60, 208-230/3/60
STANDARD ON ALL MODELS
motors ..................................................
.....................................................................................
......................................................................
New Generation "D"
see page 15 for details
INCLUDES RATINGS FOR
Page
2
2
3 - 5
6 - 11
11 - 14
15 - 20
21
22
23
24
25
26 - 29
30 - 31
32 - 33
34
35
BACK
14/10/20

Advertisement

Table of Contents
loading

Summary of Contents for KeepRite KLP Series

  • Page 1: Table Of Contents

    New Generation "D" Low Profile Evaporator PRODUCT DATA & INSTALLATION Bulletin K30-KLPD-PDI-4 Air, Electric, & Hot Gas Defrost Part # 1109283 scan: PRODUCT SUPPORT Electrical Power: web: www.k-rp.com/klp email: evaps@k-rp.com 115/1/60, 208-230/1/60, 208-230/3/60 call: 1-844-893-3222 x520 STANDARD ON ALL MODELS see page 15 for details INCLUDES RATINGS FOR CONTENTS...
  • Page 2: Nomenclature

    NOMENCLATURE KLP - LOW PROFILE EVAPORATORS KLP 3 16 L E - S2 D Design Generation Low Profile Evaporator Voltage: Number of Fans S1 = 115/1/60 T3 = 208-230/3/60 Nominal Capacity: S2 = 208-230/1/60 x 1000 @ 10°F TD, BTU/h Defrost: A = Air E = Electric...
  • Page 3: Selection Data

    SELECTION DATA - MEDIUM TEMP. MODELS KLP - LOW PROFILE EVAPORATORS R407A R407A R407C R448A R448A R449A R449A Medium Temperature - 6 FPI Models Evaporator Temperature Refrig. Charge Air Flow Selection Capacity BTU/h Model Qty. R407A R407A Fans 20/25°F 15°F 10°F (-4/-7°C) (-9°C)
  • Page 4 KLP - LOW PROFILE EVAPORATORS SELECTION DATA - LOW TEMP. MODELS R407A R407A R448A R448A R449A R449A Low Temperature - 6 FPI Models Evaporator Temperature Refrig. Charge Air Flow Model Qty. Selection Capacity BTU/h R407A R407A Fans 0°F -10°F -20°F -30°F -40°F (-18°C)
  • Page 5 SELECTION DATA - LOW TEMP. MODELS KLP - LOW PROFILE EVAPORATORS R407A R407A R448A R448A R449A R449A Low Temperature - 4 FPI Models Evaporator Temperature Refrig. Charge Air Flow Model Qty. Selection Capacity BTU/h R407A R407A Fans 0°F -10°F -20°F -30°F -40°F (-18°C)
  • Page 6: Electrical Data

    ELECTRICAL DATA KLP - LOW PROFILE EVAPORATORS 115/1/60: Air Defrost & Hot Gas Defrost with Hot Gas Loop Pan Models FAN MOTORS Model Standard EC Motors Qty. Max. Fuse Watts Total (AMPS) 104MA-S1D * 1/15 106MA-S1D * 1/15 107MA-S1D * 1/15 209M#-S1D 1/15...
  • Page 7 ELECTRICAL DATA KLP - LOW PROFILE EVAPORATORS 208-230/1/60: Air Defrost & Hot Gas Defrost with Hot Gas Loop Pan Models FAN MOTORS Model Standard EC Motors Qty. Max. Fuse Watts Total (AMPS) 104MA-S2D * 1/15 106MA-S2D * 1/15 107MA-S2D * 1/15 209M#-S2D 1/15...
  • Page 8 ELECTRICAL DATA KLP - LOW PROFILE EVAPORATORS 208-230/1/60 & 208-230/3/60: Electric Defrost Models FAN MOTORS DEFROST HEATERS Model 208-230/1/60 208-230/3/60 Standard EC Motors Total Qty. Max. Max. WATTS Max. Fuse Total Total Watts Fuse Fuse Total AMPS AMPS (AMPS) (AMPS) (AMPS) 104ME-* 1/15...
  • Page 9 ELECTRICAL DATA KLP - LOW PROFILE EVAPORATORS 115/1/60: Hot Gas Defrost with Drain Pan Heater Models FAN MOTORS DRAIN PAN HEATERS Model Standard EC Motors Max. Total Total Qty. Fuse WATTS AMPS Max. Fuse (AMPS) Watts Total (AMPS) 209M#-S1D 1/15 211M#-S1D 1/15 214M#-S1D...
  • Page 10 ELECTRICAL DATA KLP - LOW PROFILE EVAPORATORS 208-230/1/60: Hot Gas Defrost with Drain Pan Heater Models FAN MOTORS DRAIN PAN HEATERS Model Standard EC Motors Max. Total Total Qty. Fuse WATTS AMPS Max. Fuse (AMPS) Watts Total (AMPS) 209M^-S2D 1/15 211M^-S2D 1/15 214M^-S2D...
  • Page 11: Wiring Diagrams - Models With Standard Motors

    KLP - LOW PROFILE EVAPORATORS WIRING DIAGRAMS 115/1/60, 208-230/1/60: Air Defrost Models K30-KLPD-PDI-4 - 11 - 14/10/20...
  • Page 12 KLP - LOW PROFILE EVAPORATORS WIRING DIAGRAMS 208-230/1/60: Electric Defrost Models K30-KLPD-PDI-4 - 12 - 14/10/20...
  • Page 13 KLP - LOW PROFILE EVAPORATORS WIRING DIAGRAMS 208-230/1/60: Electric Defrost Models with Multiple Evaporators K30-KLPD-PDI-4 - 13 - 14/10/20...
  • Page 14 KLP - LOW PROFILE EVAPORATORS WIRING DIAGRAMS 115/1/60, 208-230/1/60: Hot Gas Defrost Models K30-KLPD-PDI-4 - 14 - 14/10/20...
  • Page 15: Wiring Diagrams - Models With

    KeepRite Refrigeration's ESP+ intuitive evaporator control technology is designed to replace traditional electro-mechanical refrig- eration controls typically used on medium and low temperature applications. By combining award winning adaptive technology along with an electronic expansion valve, KeepRite Refrigeration continues to be The Right Choice For The Refrigeration Profes- sional.
  • Page 16 KLP - LOW PROFILE EVAPORATORS WIRING DIAGRAMS 115/1/60: Air Defrost Models with K30-KLPD-PDI-4 - 16 - 14/10/20...
  • Page 17 KLP - LOW PROFILE EVAPORATORS WIRING DIAGRAMS 208-230/1/60: Air Defrost Models with K30-KLPD-PDI-4 - 17 - 14/10/20...
  • Page 18 KLP - LOW PROFILE EVAPORATORS WIRING DIAGRAMS 208-230/1/60: 1-3 Fan Electric Defrost Models with Max.12A K30-KLPD-PDI-4 - 18 - 14/10/20...
  • Page 19 KLP - LOW PROFILE EVAPORATORS WIRING DIAGRAMS 208-230/1/60: 4-5 Fan Electric Defrost Models with 16A to 20A K30-KLPD-PDI-4 - 19 - 14/10/20...
  • Page 20 KLP - LOW PROFILE EVAPORATORS WIRING DIAGRAMS 208-230/1/60: 6 Fan Electric Defrost Models with K30-KLPD-PDI-4 - 20 - 14/10/20...
  • Page 21: Annual Walk-In Energy Factor (Awef) Ratings

    AWEF RATINGS KLP - LOW PROFILE EVAPORATORS Annual Walk-In Energy Factor Ratings - Medium Temperature If a numerical value is listed in the table below, the following statement applies to that corresponding model: " This refrigeration system is designed and certified for use in walk-in cooler applications.” Model R404A R407A...
  • Page 22: Dimensional Data

    DIMENSIONAL DATA / SPECIFICATIONS KLP - LOW PROFILE EVAPORATORS .438 SLOTS IN MOUNTING BRACKETS 6 1/2 6 1/2 [165] [165] REFRIGERATION [102] ELECTRICAL CONNECTIONS. AIR THROW 15 7/8 APPROX 35' CONNECTIONS. SUCTION & LIQUID. [403] IN OPEN SPACE 1, 2 AND 3 FAN MODELS.
  • Page 23: Shipping Weights

    SHIPPING WEIGHTS KLP - LOW PROFILE EVAPORATORS Air Defrost and Hot Gas Defrost with Drain Pan Heater Models SHIPPING WEIGHT MODEL NUMBER KLP (kg) 104MA (20) 106MA (21) 107MA (22) 209MA 209MT 209MG 207LG 207LT 207VG 207VT (32) 211MA 211MT 211MG 209LG 209LT...
  • Page 24: Recommended Expansion Valve Selections

    RECOMMENDED THERMAL EXPANSION VALVE SELECTIONS KLP - LOW PROFILE EVAPORATORS Medium Temperature Models R404A R507 R407A R407A R407C R449A R449A Model R448A R448A SPORLAN SOLENOID VALVES SPORLAN SOLENOID VALVES EBQSE-AA-C EBQVE-AAA-C 104MA-S1D EBQSE-A-C EBQVE-AA-C 106MA-S1D EBQSE-A-C EBQVE-AA-C 107MA-S1D EBQSE-A-C EBQVE-A-C 209MA-S1D EBQSE-B-C EBQVE-A-C...
  • Page 25: Expansion Valve Selections - Models With

    FACTORY INSTALLED EXPANSION VALVE SELECTIONS KLP - LOW PROFILE EVAPORATORS Models with Medium Temperature Air Or Electric Defrost All Refrigerants FACTORY FACTORY MODEL FACTORY INSTALLED INSTALLED INSTALLED LIQUID LINE EXPANSION NOZZLE SOLENOID VALVE VALVE 104M*** E2V9 106M*** L1/2 E2V11 107M*** L1/2 E2V14 209M***...
  • Page 26: Defrost Kit And Fuse Package Selections / Details

    DEFROST KIT & FUSE PACKAGE SELECTIONS KLP - LOW PROFILE EVAPORATORS Medium Temperature, 6 FPI 1 X EVAPORATOR 2 X EVAPORATOR Model Defrost Fuse Defrost Fuse Voltage Package Package 104ME-S2D 208-230/1/60 DFK-02 FP-004 DFK-06 FP-008 104ME-T3D 208-230/3/60 DFK-03 FP-013 DFK-07 FP-018 106ME-S2D 208-230/1/60 DFK-02...
  • Page 27 208-230/3/60 DFK-03 FP-014 DFK-07 FP-019 627VE-S2D 208-230/1/60 DFK-02 FP-020 DFK-09 FP-021 627VE-T3D 208-230/3/60 DFK-03 FP-014 DFK-07 FP-019 For info on matched KeepRite condensing units, visit www.k-rp.com/cu Defrost Kit & Fuse Package Online Selection Tool: www.k-rp.com/dfk K30-KLPD-PDI-4 - 27 - 14/10/20...
  • Page 28 DEFROST KIT & FUSE PACKAGE SELECTIONS KLP - LOW PROFILE EVAPORATORS Defrost Kits Number of Kit Part Evaps. Number Description DFK-01 Time Clock, HtrCont - 1x 40A (3P), FB 1x 30A (1P) DFK-02 Time Clock, HtrCont - 1x 40A (3P), FB 1x 30A (2P) DFK-03 Time Clock, HtrCont - 1x 40A (3P), FB 1x 30A (3P) DFK-04...
  • Page 29 DEFROST KIT & FUSE PACKAGE SELECTIONS KLP - LOW PROFILE EVAPORATORS Fuse Packages Package Package Part Part Number Description Number Description FP-001 FUSES (1) 15AMP FP-054 FUSES (3)15AMP (6) 35AMP FP-002 FUSES (1) 20AMP FP-055 FUSES (2) 15AMP (2) 45AMP FP-003 FUSES (1) 25AMP FP-056...
  • Page 30: Installation Instructions

    INSTALLATION INSTRUCTIONS KLP - LOW PROFILE EVAPORATORS INSTALLATION 1. Determine actual evaporator capacity. The installation and start-up of evaporators should only be The nominal rating is based at 10°F T.D. (5 .6°C) (Entering Air performed by qualified refrigeration mechanics. This equipment Temp. minus Evap. Temp.) Note that a higher/lower operating should be installed in accordance with all applicable codes, ordi- T.D.will increase / decrease this capacity rating by their direct nances and local by-laws.
  • Page 31 INSTALLATION INSTRUCTIONS KLP - LOW PROFILE EVAPORATORS DRAIN LINE MAINTENANCE The drain line should be run from the drain connection, sloping The unit should be periodically inspected for any dirt or ice build- at least 1” (25 mm) per foot and should have the size at least as up on the fin surface and cleaned if large as the drain connection.
  • Page 32: Hot Gas Piping Schematics

    HOT GAS PIPING SCHEMATICS KLP - LOW PROFILE EVAPORATORS Standard Configurations - Refer to Nomenclature for details REVERSE CYCLE DEFROST 3-PIPE DEFROST WITH HOT GAS DRAIN PAN LOOP WITH HOT GAS DRAIN PAN LOOP WITH CHECK VALVE LOOSE WITH CHECK VALVE LOOSE EVAPORATOR COIL EVAPORATOR COIL DISTRIBUTOR...
  • Page 33 HOT GAS PIPING SCHEMATICS KLP - LOW PROFILE EVAPORATORS Optional Configurations - Refer to Nomenclature for details REVERSE CYCLE DEFROST 3 PIPE DEFROST WITH HOT GAS DRAIN PAN LOOP WITH HOT GAS DRAIN PAN LOOP WITH CHECK VALVE MTD. & CONNECTED TO LOOP CHECK VALVE MOUNTED WITH TXV BY OTHERS OR FACTORY INSTALLED COMPLETE ASSY PROVIDED WHEN TXV IS MTD...
  • Page 34: Project Information

    PROJECT INFORMATION KLP - LOW PROFILE EVAPORATORS System Model Number Date of Start-Up Serial Number Service Contractor Refrigerant Phone Electrical Supply E-mail K30-KLPD-PDI-4 - 34 - 14/10/20...
  • Page 35: Product Support Resources: Service Parts, Troubleshooting, Warranty, Etc

    PRODUCT SUPPORT RESOURCES KLP - LOW PROFILE EVAPORATORS web: www.k-rp.com/klp email: evaps@k-rp.com call: 1-844-893-3222 x520 email: troubleshooting@k-rp.com call: 1-844-893-3222 x529 web: www.k-rp.com/parts email: parts@k-rp.com call: 1-844-893-3222 x520 web: www.k-rp.com/warranty email: warranty@k-rp.com call: 1-844-893-3222 x507 email: orders@k-rp.com call: 1-844-893-3222 x501 email: shipping@k-rp.com call: 1-844-893-3222 x503 HOW CAN WE HELP YOU? visit www.k-rp.com/contact...
  • Page 36: As Built" Service Parts List

    KLP - LOW PROFILE EVAPORATORS Service Parts List Label To Be Attached HERE KeepRite Refrigeration Brantford, ON • Longview, TX 1-800-463-9517 info@k-rp.com www.k-rp.com Due to the manufacturer’s policy of continuous product improvement, we reserve the right to make changes without notice. 14/10/20...