We are delighted that you have purchased this PIR Light. This light
is suitable for indoor or outdoor use. Please read this instruction
manual before installation and retain for future reference.
IMPORTANT: Never modify the unit, there are no user serviceable
parts inside. Not suitable for use with dimmer switches. Install in
accordance with IEC Wiring Regulations.
THE LIGHT SHOULD BE INSTALLED BY A QUALIFIED
ELECTRICIAN.
210¡ ã
Occupancy 3m
10m
Fig.1 Detection Area
1.8-2.5m
OCCUPANCY
The PIR Sensor has an Occupancy Range of Radius 3 meters. In this
range, the sensor will detect small movement.
If you want to achieve best results, we suggest you take into account the
following points:
1. The Occupancy Range is 3 meters.
2. We suggest the delay time must be set more than 10 minutes.
3. The PIR Sensor must worked at 25˚c or lower and dry weather
(normal temperature)
POSITIONING THE LIGHT
When selecting the mounting position, take into account the
following points:
1. The sensor is designed for optimum performance when mounted at a
height of between 1.8.5 to 2.5 meters (see Figure 1)
2. Avoid pointing at or positioning close to heat sources such as heaters
or heat extraction units, which may cause false triggering.
3. Avoid pointing at bright lights as the PIR sensor will not function when
you set Lux control level to dark ( position).
4. Avoid mounting at strong electromagnetic disturbance, i.e. near
electrical motor or fluorescent lamp ballast.
INSTALLING THE LIGHT
Before commencing any electrical work, ensure the mains supply is
isolated by switching off and removing the relevant fuse. (See Figure
2 A ,B and C)
A.B. Wall and Ceiling Mounting(Figure 2A and B)
1. Use a screwdriver to remove the bottom
2. Remove the Junction Box and Terminal Block
3. Use the Bottom Cover to mark the position of screw holes onto
mounting surface. Drill the wall to depth of about 35mm and fit the
plastic plugs, and then fix the Bottom Cover to the mounting surface
with rightly screws. Care should be taken to avoid drilling or screwing
into concealed electrical wiring.
SL04B Instructions Rev01

Advertisement

loading

Summary of Contents for Challenger SL04B

  • Page 1 Drill the wall to depth of about 35mm and fit the plastic plugs, and then fix the Bottom Cover to the mounting surface Occupancy 3m with rightly screws. Care should be taken to avoid drilling or screwing into concealed electrical wiring. Fig.1 Detection Area SL04B Instructions Rev01...
  • Page 2 2. Remove the Junction Box and Terminal Block 6. Fit the Bottom Cover onto the corner mounting support 3. Use the corner mounting support to mark the position of screw holes 7. Fit the main body onto the Bottom Cover SL04B Instructions Rev01...
  • Page 3 Note: Once the light has been triggered by the PIR sensor any subsequent detection will start the timed period again from the beginning. ADJUSTING THE SENSITIVITY: The sensitivity means the Maximum distance which PIR Sensor can be triggered by movement body. Turning SL04B Instructions Rev01...
  • Page 4 Due to our policy of continuous improvement we reserve the right to change specification without prior notice. Errors and omissions excepted. These instructions have been carefully checked prior to publication. However, no responsibility can be accepted by Challenger Security Products for any misinterpretation of these instructions. CHALLENGER SECURITY PRODUCTS...