Installation must be carried out by qualified
electricians or skilled/competent person who is
familiar with the appropriate standards and
MOTION DETECTOR LIGHT CONTROL
technical requirements of the appliance and its
proper installation.
SL01/SL01B/SL02/
Contact a qualified electrician in the event of
SL02B/SL03/SL03B
fault or break down.
CAUTION!
A circuit breaker (250VAC, 10A) type C according to
EN60898-1 of load shall be installed in the fixed wiring
for protection.
Do not mount on conductive surface.
Do not open the enclosure frequently.
Turn off power when replacing lamps.
High in-rush current would occur when lamps of certain
brands used which may damage the unit permanently.
1
PACKAGE CONTENTS
SL01, SL01B / SL02, SL02B
INSTRUCTION MANUAL
Rubber
Pattern
washer
TECHNICAL SPECIFICATIONS
Rated Voltage
230V~50Hz
Wood screws
Lens
Load
SL01, SL01B / SL02, SL02B:
Item
Detector
shields
+ Rubber
Max. 5A (cos =1)
washers
Incandescent Lamp: Max. 1000W
HV Halogen Lamp: Max. 500W
Quantity
1
2
LED Lamp: Max. 120W
Energy Saving: 200VA(include
SL03, SL03B
CFL and PL Lamp)
SL03, SL03B:
Max. 8A (cos =1)
Pattern
Incandescent Lamp: Max. 1840W
HV Halogen Lamp: Max. 1000W
LV Halogen Lamp: Max. 300VA
Fluorescent Lamp: Max. 400VA
Screws
(Uncompensated)
Item
Detector
3.5 x 10MM
LED Lamp: Max. 150W
Energy Saving: 200VA(include
CFL and PL Lamp)
Quantity
1
2
Installation height
2.0 - 3.0M, recommended
installation height is approx. 2.5M
Detection angle
SL01, SL01B: up to 110
O
Pattern
SL02, SL02B: up to 180
O
SL03, SL03B: up to 270
O
Corner
Lens
Item
LUX
From"
" (approx. 5LUX) to "
"
mounting
shields
Adjustment
(
)
bracket
Auto OFF
" Test ",
from " - " (approx.6sec) to
Quantity
1
3
Time Delay
" + "
(approx.10min) and "
"
Meter
Adjustment
Max. 10M
LED Mode
OFF / Warning / Watch
2
Power Consumption
Approx. 1W
PRODUCT DESCRIPTION
Operating Temperature -20 C to +45 C
o
o
SL01, SL01B, SL02, SL02B, SL03, SL03B are passive infra
Environmental
IP44
red sensors to switch various types of load upon detection
Protection
of movement. Suitable for indoor or outdoor use and used
in residential or commercial environments.
2.1 Features
Ceiling mount
4 Programmable display LED's show the detector state.
Side view
Choose different configurations to show detector is in
standby or test mode. They can also be turned off if not
required.
Can be wall or ceiling mounted. SL03 & SL03B can also
be corner (internal & external) mounted with the supplied
corner bracket.
Unique design for multi-direction sensing including up /
0.5M 0 0.5M
down / forward / sideways adjustment.
3 versions available with different detection angles.
Various types of lighting load can be connected to suit
most applications.
Wall mount
Lens shield equipped for easy detachment and fixing
enables a precise adjusting of the detection zone.
Side view
2.2 Dimension
Detector : 129
x
80
x
63MM (See FIG.1-A)
0.5M 0 0.5M
Ceiling mount
Side view
80
63
MOT ION DETECTOR LIGHT CONTRO L
SL01/SL01B/SL02/
SL02B/SL03/SL03B
FIG.1-A
Wall corner mounting bracket (Optional purchase) 80 74 5 28mm
x
x
(See FIG.1-B)
4 25.4MM
x
Manual
80mm
28mm
0.5M 0 0.5M
2
1
Wall mount
FIG.1-B
Side view
Rubber
washer
Wood screws
3
INSTALLATION AND WIRING
4 25.4MM
x
+ Rubber
washers
Please disconnect power completely and read the
2
entire instruction manual carefully before installation.
7M
3.1 Select a proper location
MOT ION DETECTOR LIGHT CONTRO L
SL01/SL01B/SL02/
SL02B/SL03/SL03B
Ceiling mount
3.1.1
It is recommended to install the detector at the height
of 2 - 3M. The detection range can reach up to 10M,
the
inner coverage is a circular with radius of 0.5M.
Side view
Manual
O
SL01, SL01B detection angle: 110 (See FIG.2-A).
O
SL02, SL02B detection angle: 180 (See FIG.2-B).
SL03, SL03B detection angle: 270 (See FIG.2-C).
O
1
Wall mount
Side view
Top view
7M
110
o
10M
10M
3.1.2 Helpful tips for installation.
0.5M 0 0.5M
10M
0
R0.5M
As the detector responds to temperature change, please
avoid the following conditions (see FIG.3):
Avoid directing the
detector
toward the objects whose
surfaces are highly reflective, such as mirror, monitor, etc.
Avoid mounting the detector near heat sources, such as
Top view
heating vents, air conditioners, vents , lights, etc.
o
110
Avoid aiming the detector towards objects which may
move in the wind, such as curtains, tall plants, trees etc.
10M
10M
10M
0
R0.5M
FIG.2-A (SL01, SL01B)
Top view
180
o
10M
10M
0 R0.5M
10M
Top view
180
o
10M
10M
0 R0.5M
10M
FIG.2-B (SL02, SL02B)
FIG.3
3.1.3 Pay attention when testing, the detection area is more
sensitive cross the detector up to 10 , and towards the
m
Top view
detector across up to 1m (See FIG.4).
270
O
More sensitive to movement
Less sensitive to movement
across the pattern
directly towards detector
R0.5M
0.5M 0 0.5M
10M
10M
10M
FIG.4
Top view
3.2 Wiring (See FIG.5)
270
O
Verify carefully and make sure the wires are connected
correctly.
3.2.1 Type 1:
L
230V~50Hz
R0.5M
N
0.5M 0 0.5M
10M
10M
10M
Load
FIG.2-C (
SL03, SL03B
)
L
L
N
N
3.2.2 Type 2:
3.3.1.4 Put wood screws into the rubber washer,and fix
the bottom case on the wall or ceiling,
L
up the front cover and tighten it with screws.
230V~50Hz
N
(See FIG.8).
Load
L
L
N
N
FIG.5
3.3 Installation procedure
SL01, SL02, SL03 can be installed on the wall directly,
recess / corner with wall bracket, (SL03, SL03B only) or on
Rubber
the ceiling directly.
washer
NOTE
Motion detector
SL01, SL02, SL03,
is factory default for
FIG.8
wall mount.
NOTE
3.3.1 Wall mount
DO NOT remove the rubber strip and make sure it lines
3.3.1.1
Unscrew the front cover by screwdriver.
up with the front cover perfectly (See FIG.8).
3.3.1.2 To insert the "-" head screwdriver blade into the gap
There should be a click sound, this identifies that the
between front cover and bottom case, then rotate
upper hook has been fastened into the slot (See FIG.9-A),
anti-clockwise 90
to detach the front cover
and a second click sound shows the lower hook has been
(See FIG.6).
fastened into the slot ( See FIG.9-B). Please ensure front
cover is locked well on bottom case (See FIG.9-C),
IMPORTANT NOTE - If not (See FIG.9-D), water will
enter into the inside of product and will cause damage to
the unit and there is potential of electrical shock.
Hook
Slot
Slot
Hook
Click
FIG.6
3.3.1.3 Cut the cable entry knock-out by a pliers or cutters
(See FIG.7-A), and feed cables through cable entry
knock-out and rubber gasket, then refer to wiring
diagram (See FIG.5) to connect power cables, and
please be noted to strip off 6 - 8MM of cable
sheathing (See FIG.7-B).
FIG.9-A
FIG.7-A
Cable entry
knock-out
Cable entry
knock-out
FIG.7-B
Earth terminal
FIG.9-B
6-8MM
L'
L
N
N
METER
Warning
Test
1S.
TIME
OFF
Watch
LED Mode
Rubber
LUX
Rubber
gasket
gasket
FIG.9-C
3.3.2
Corner / recess mount with wall bracket.
3.3.2.1 8-knock-out
wall bracket is designed for various
then cover
application ( See FIG.10), break the knock-out to
feed the wires through the corresponding hole.
Screw support
3
1-8 holes are
1
4
screw
2
Front cover
knock-outs
inside view
Cable entry
knock-out
5
6
7
8
Cable entry
knock-out
Rubber strip
FIG.10
3.3.2.2 Break screw knock-outs (See FIG.10), then fix the
wall bracket onto recess / corner with wood screws
(See FIG.11-A & FIG.11-B), make sure "UP"mark
upwards. refer to 3.3.1.1 - 3.3.1.3 to connect power
cables, and fix the bottom case on wall bracket
(See FIG.12), then assembly front cover.
Corner installation
Click
FIG.11-A
Recess installation
FIG.11-B
Click
Rubber
washer
FIG.9-D
FIG.12

Advertisement

loading

Summary of Contents for Challenger SL01

  • Page 1 Wall mount EN60898-1 of load shall be installed in the fixed wiring Lens shield equipped for easy detachment and fixing SL01, SL02, SL03 can be installed on the wall directly, for protection. enables a precise adjusting of the detection zone.
  • Page 2 LEDs all in turn. mount (See FIG.14). turn on range. BLACKPOOL base 1sec signal once SL01, SL02, SL03 is triggered, then OFF. Warning 2. No power 2. Switch on the power. FY4 4NB edge the light ON 1sec, OFF 9sec.

This manual is also suitable for:

Sl02Sl01bSl02bSl03Sl03b