Samson 42-10 Mounting And Operating Instructions page 56

Rs check valve (backflow protection)
Table of Contents

Advertisement

Servicing
Note
The regulator was checked by SAMSON
before it left the factory.
− Certain test results certified by SAMSON
lose their validity when the regulator is
opened. Such testing includes seat leakage
and leak tests.
− The product warranty becomes void if
service or repair work not described in
these instructions is performed without
prior agreement by SAMSON's After-sales
Service.
− Only use original spare parts by
SAMSON, which comply with the original
specifications.
Tip
SAMSON's After-sales Service can support
you in drawing up an inspection and test
plan for your plant.
9-2
Legend for Fig. 9-1
1
Valve body
2
Seat
3
Plug
4
Plug stem
5
Threaded connection for diaphragm actuator
6
Actuator stem
7
Diaphragm stem
10 Actuator housing
10.1 Distance ring
11 Two diaphragms
11.1 Operating diaphragm for upstream pressure
11.2 Operating diaphragm for downstream pressure
12 Diaphragm rupture indicator
13 Set point springs
13.1 Force limiter
14 Control line 8x1 mm
15 Spacer bushing including seal
Housing bolts (two long bolts opposite each other,
16
DN 15 to 25/NPS ½ to 1 only)
16.1 Top housing bolts
16.2 Bottom housing bolts
17 Diaphragm plate nut
18 Pressure switch (optional, not shown)
19 Compensation chamber (optional)
20 Filler plug
21 Screw fitting (control line)
EB 3009 EN

Advertisement

Table of Contents
loading

Table of Contents