Technical Data - Samson 42-10 Mounting And Operating Instructions

Rs check valve (backflow protection)
Table of Contents

Advertisement

3.2 Technical data

The valve and actuator nameplates provide
information on the valve and actuator ver-
sions (see the 'Markings on the device' sec-
tion).
Note
More information is available in Data Sheet
u T 3009.
Conformity
The Type 42-10 RS Regulator bears both the
CE and EAC marks of conformity.
Process medium and scope of application
The Type 42-10 RS Check Valve is used to
prevent the backflow protection of a medi-
um.
− For liquids, gases and vapors
− Compressed air and nitrogen up to
80 °C · 150 °C
 2)
− Saturated steam with compensation
chamber up to 220 °C/430 °F
− Liquids up to 80 °C/175 °F
− Differential pressure set point
Δp = 0.2 bar · 0.3 bar
− Valve sizes DN 15 to 250/NPS ½ to 10
− Pressure ratings PN 25 to 40/Class 150
and 300
EB 3009 EN
/175 °F · 300 °F
 2)
/3 psi · 5 psi
 1)
Design and principle of operation
The regulator is closed when relieved of
pressure. The regulator is open when the up-
stream pressure is greater than the down-
stream pressure. The regulator closes when
the downstream pressure rises.
Leakage class
The soft-seated regulator has the leakage
class VI according to IEC 60534-4.
Temperature range
Depending on how the regulator is config-
ured, it can be used up to temperatures of
220 °C/430 °F (see Table 3-1). The mini-
mum temperature is limited by the accesso-
ries used and the actuator's diaphragm ma-
terial (u T 3009).
Noise emissions
SAMSON is unable to make general state-
ments about noise emissions. The noise emis-
sions depend on the regulator version, plant
facilities, process medium and operating
conditions.
Dimensions and weights
Fig. 3-4 provides a summary of the dimen-
sions and weights. The lengths and heights
in the dimensional drawings are shown on
pages 3-8 to 3-9.
 1)
DN 200 and 250/NPS 8 and 10 version
1)
Version with FKM diaphragm
2)
3-5