Additional Information; Assembly And Installation - LEGRAND CHIEF PAC527L Series Installation Instructions Manual

In-wall box w/leverlock and accessories
Table of Contents

Advertisement

PAC527L Series
OPTIONAL PARTS PER CUSTOM CONFIGURATION (NOT INCLUDED)
Conduit connectors
Conduit pipe 1/2", 1" or 1-1/4"

ADDITIONAL INFORMATION

NOTE: Grounding screw installed at factory in PAC527L, PAC527LF, PAC527LFC, PAC527LFxP4, and
PAC527LFxP6 in-wall boxes. Grounding screw is located on one side of the PAC527L box.
grounding screw

ASSEMBLY AND INSTALLATION

IMPORTANT ! : In the following instructions, the
reference to PAC527L includes the following models:
PAC527L
PAC527LF
PAC527LFC
PAC527LFxP4
PAC527LFxP6
The PAC527L is intended for use in both installations where an
existing finished drywall wall is present, and where the wall
surface has not been finished and the structural studs are
exposed. The wall then must be finished around the opening of
the box after the box has been installed.
WARNING:
performed by a licensed electrician following
all local codes and ordinances.
Locating PAC527L
1.
Identify a suitable wall location for the accessory.
2.
Locate and mark studs using a stud sensor.
3.
Identify possible structural conflicts (electrical wiring,
plumbing, gas lines, HVAC).
7
10-32
Earthing symbol IEC 60418 No. 5019
affixed adjacent to grounding terminal
All wiring should be
Electrical
3" x 2" Steel Old
Work Switch Box
(2" deep)
Raco #420 or
equivalent
WARNING:
ELECTRICAL SHOCK HAZARD! CUTTING
OR DRILLING INTO ELECTRICAL WIRES OR CABLES
CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY!
ALWAYS make certain area behind mounting surfaces is free
of electrical wires and cables before cutting, drilling or
installing fasteners.
WARNING:
EXPLOSION AND FIRE HAZARD! CUTTING
OR DRILLING INTO GAS PLUMBING CAN CAUSE DEATH
OR SERIOUS PERSONAL INJURY. ALWAYS make certain
area behind mounting surfaces is free of gas, water, waste or
any other plumbing before cutting, drilling or installing
fasteners.
4.
Determine all additional/optional components required:
Conduit pipe
Conduit connectors (both large and small)
Electrical box(es) (3" x 2")
Steel electrical box cover(s)
Electrical outlet(s)
Installation Instructions
Narrow Handy Box
outlet
Cover, Duplex
Raco #864 or
equivalent

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents