Haier AS25S2SN1FA-NR Operation Manual

Haier AS25S2SN1FA-NR Operation Manual

Split type room air conditioner
Hide thumbs Also See for AS25S2SN1FA-NR:

Advertisement

SPLIT TYPE ROOM AIR CONDITION
OPERATION MANUAL
Please read this operation manual before using the air conditioner.
Keep this operation manual for future reference.
0011500387
ER
AS25S2SN1FA-NR
AS35S2SN1FA-NR
AS50S2SN1FA-NR

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AS25S2SN1FA-NR and is the answer not in the manual?

Questions and answers

Summary of Contents for Haier AS25S2SN1FA-NR

  • Page 1 SPLIT TYPE ROOM AIR CONDITION OPERATION MANUAL AS25S2SN1FA-NR AS35S2SN1FA-NR AS50S2SN1FA-NR Please read this operation manual before using the air conditioner. Keep this operation manual for future reference. 0011500387...
  • Page 4: Parts And Functions

    Parts and Functions Indoor Unit Remote controller Air Purifying Filter Outer side of the controller (inside) Inlet ON / OFF button Emergency o i t Inlet grille Switch status Outlet 7. O peration mode display 8. WIFI and CLOCK display Horizontal flap 9.
  • Page 7: Operation

    Operation button. pressed, temp. setting increases 1 ºC. pressed, temp. setting decreases 1 ºC. TIMER TIMER TURBO TURBO TURBO TURBO Unit will start running to reach the SELF CLEAN temp. setting on LCD. SELF CLEAN SELF CLEAN SELF CLEAN A N O pe ration Functional description the purpose of this function is to clean the evaporator.
  • Page 13: Disposal Requirements

    IMPORTANT INFORMATION REGA- EUROPEAN REGULATIONS RDING THE REFRIGERANT USED CONFORMITY FOR THE MODELS Contains fluorinated greenhouse gases Voltage:230V Climate:T1 covered by the Kyoto Protocol All the products are in conformity with the following European provision: 1+2= - 2014/53/EU(RED) - 2014/517/EU(F-GAS) This product contains fluorinated greenhouse gases covered by the Kyoto Protocol.
  • Page 14: Indoor Unit Installation

    Indoor Unit Installation Necessary Tools for Installation Power Source Torque wrench Driver Before inserting power into receptacle, check the voltage without (17mm,22mm,26mm) Nipper fail. Pipe cutter Hacksaw The power supply is the same as the corresponding nameplate. Flaring tool Hole core drill Install an exclusive branch circuit of the power.
  • Page 19: Troubleshooting

    30 seconds later, cutting off the power. Are there too much heat sources or too many people in the room during cooling operation? Haier Address:No.1 Haier Road,Hi-tech Zone,Qingdao 266101 P.R.China Contacts: TEL +86-532-8893-6943;FAX +86-532-8893-1010 Website: www.haier.com...