• If a sink strainer is straight below the faucet sensor, use a strainer with a non- their design, are the property of Stern Engineering Ltd or other third parties and you are not permitted to use them without the prior written consent of Stern Engineering Ltd or such third party as may own them.
100 - 3800 Standard soap discharge 0.8cc, Adjustable Security time (faucet) 90 seconds. Adjustable. Hot water temperature max. 70ºC ALLEN KEY FOR HAND Code Number 280400 DRYER COvER. The SWAR System can be ordered with or without the Hand Dryer (QTY: 1)
Note: Before installing the SWAR, flush water lines and shut off all valves. Notes: Thoroughly flush the water supply lines before connecting them to the SWAR. Step 1 – WaLL moUNtiNG Do not allow dirt, Teflon tape or metal particles to enter the faucet.
Page 5
FiLLiNG tHe Soap taNk Step 5– FiLLiNG tHe Soap taNk Step 4 – poWeriNG tHe SyStem Important Note: The SWAR’s sensors Unscrew the cover of the soap bottle are self-adjusting; therefore, the ideal and fill with liquid soap. sensor range for a given location will be set automatically.
maiNteNaNce Spare partS LiSt FAUCET MAINTENANCE 12V TRansfoRmeR 06522081 Filter Cleaning Instructions This faucet is provided with a stainless steel filter preventing foreign particles from FaUcet entering the lines. It is recommended to clean the filters every six (6) months. If the water flow has decreased, this may be because the filter is clogged.
FUNctioNS - Soap & Water remote coNtroL FUNctioNS - Soap & Water Stern’s advanced 13 keys remote control enables adjustments of products including a self-adjusting or dual flush sensor. The following settings can be adjusted and the following functions can be performed:...
Page 8
remote coNtroL FUNctioNS - Soap & Water remote coNtroL FUNctioNS - LiGHt 1-4 DROP KEY: The 1-4 drop keys allow the user to choose the desired Description: soap quantity at liquid soap dispensers.* The LED color selector kit is used to control the color of the LED lighting. This selector kit has several functions such as gradually changing lighting, flash and fade.
Decrease the range. LED in the sensor Unit is in “Security mode”: If the If a defect is found in normal use, Y. Stern Engineering Ltd. will, at its discretion, repair, does not flash sensor is covered for more than 90 To return to normal operating provide a replacement part or product, or make appropriate adjustments.
Page 10
troUBLeSHootiNG - Soap DiSpeNSer troUBLeSHootiNG - HaND Dryer proBLem iNDicator caUSe SoLUtioN proBLem correctiVe actioNS Soap has run low or Refer to page 8 and refill the HAZARD: BE SURE TO TAKE SUITABLE PRECAUTIONS TO AvOID SHOCK. completely out. soap tank. First ensure that the breaker supplying the power to the dryer is operational.