Appendix B: Radia Lighting Programming

Ramp To Level

This function ramps the specified dimmer(s) to the specified level over the optionally specifiable time.
Ramp To Level
String:
Response:
Examples:

Undefine Dimmer

This function "undefines" the specified dimmer so that it will not be included in the next saved preset.
This allows a preset to affect a subset of the dimmers rather than all of them.
Undefine Dimmer
String:
Response:
Example:
86
<dimmer>L<level>[T<time>]
<dimmer> LEVEL <level> IN <time>
SEND_STRING Radia,"'2L88',13"
Response:
"12,'02 LEVEL 088 IN 005',13,10,'?'"
SEND_STRING Radia,
"'1-4&6L100',13"
Response: "12,'GROUP LEVEL 100 IN 005',13,10,'?'"
SEND_STRING Radia,"'6L50T5',13"
Response: "12,'06 LEVEL 050 IN 005',13,10,'?'"
SEND_STRING Radia,"'AL0',13"
Response: "12,'ALL LEVEL 000 IN 005',13,10,'?'"
<dimmer>LU
<dimmer> LEVEL UN IN 000
SEND_STRING Radia,"'1LU',13"
Response: "12,'001 LEVEL UN IN 000',13,10,'?'"
SEND_STRING Radia,"'2-4LU',13"
Response: "12,'GROUP LEVEL UN IN 000',13,10,'?'"
SEND_STRING Radia,"'ALU',13"
Response: "12,'ALL LEVEL UN IN 000',13,10,'?'"
Ramp dimmer 2 to 88% at the default
level rate
Assuming default level rate is 5
Ramp 1-4, & 6 to 100% at the default
level rate.
Ramp dimmer 6 to 50% over 5 seconds.
Ramp all dimmers to 0% at the default
ramp rate.
Set dimmer 1 to undefined level
Set dimmers 2-4 to undefined level
Set all dimmers to undefined level
RE-DM4 and RE-DM6 RADIA Eclipse Dimmer Modules