Filter change:
 Loosen cap nut with help of filter head screw
 Remove filter and dispose of it
 Insert new filter cartridges
 Pay attention to correct fit and cleanliness of the seal ring
 Tighten cap nut by hand
The suction hoses, pumps, filter housings and filter are contaminated after the first
use. Repairs and maintenance must only be executed under the observance of all
relevant safety measures. All the filters mentioned have to be disposed of
according to the respective legal terms.

7.3 Reduction of legionella growth

To avoid excessive legionella growth, we recommend to heat the water in the tank to a
temperature around >60°C once or twice a week.
To clean the hoses and the shower, the heated water should also be removed from the
shower for about 3 minutes.
Caution risk of scalding!
Alternatively, an approved disinfectants can also be used.