7.1 Daily maintenance

 Check hoses for free flow
 Visual check of 220µ-Pre filter for dirt
 Control of fine filter via manometer

7.2 Filter change

The Manometer controls the fine filter. We recommend a filter change at approx. 3bar.
Attention:
 Change Filter only when device is switched off
 Demount dirty filters only in wet state to avoid contamination
 Use approved filters only
 Do not use damaged filter cartridges
Instruction manual
Water treatment boiler system C 130 L

7 Maintenance and care

Cap nut
Manometer filter control
Filter head screw
page 11