LG LS-B0760CM/B0760HM Service Manual page 28

Table of Contents

Advertisement

3) Connection of Pipings(11K,12K, 14K BTU)
1. Remove the indoor tubing with Drain hose to the
hole
• Remove tubing holder and pull the tubing out of the
chassis.
For right rear piping
3. Route the tubing and the drain hose straight
backwards(see figure).
4. Insert the connection cable into the indoor unit
through the piping hole.
Outdoor
Indoor
Connecting cable
Drain pipe
Tubing holder
11K, 12K, 14K Series
• To remove the holder, press
the bottom of the chassis
near the holder upwards and
the tab is clear of its hole.
• Turn it clockwise approx.
90°C and remove it.
Connecting piping
2. Refix the tubing holder into original position.
Pull
Press
• Do not connect the cable to the indoor unit.
• Make a small loop with the cable for easy connec-
tion later.
5. Tape the tubing, drain hose and the connecting
cable.
Connecting
cable
- 28 -
Taping
Indoor/Outdoor
Connecting cable
Gas side piping
Liquid side piping
Drain hose

Hide quick links:

Advertisement

Table of Contents
loading