Note:
Always apply the supply voltage together with the control inputs.
24 V AC/ 115/ 230 V AC: Apply phase "L" of the supply voltage to the control inputs C1 / C2.
Only 48 V AC: Apply "N" of the supply voltage to the control inputs C1 / C2.
Operating voltage
7.1.2
Stage selection by supply via control input (TAV) – all DC versions
Note:
Only applicable to DC version!
The sounder can be supplied with operating voltage via the control inputs C1 / C2 on the connection board.
Supply and stage selection therefore take place simultaneously.
Switch setting should be as follows:
S1A to
(diode not bridged)
Changeover switch S1B to "+"
Connect the negative terminal on the connection board.
Connect the positive terminal on the connection board. The basic tone (♪) is generated.
Connection of the positive voltage to C1 on the connection board generates tone C1.
Connection of the positive voltage to C2 on the connection board generates tone C2.
Simultaneous connection of the positive voltage to C1 and C2 on the connection board generates tone
"C1+C2".
06/2020
Operating instructions PA 1 / PA X 1-05
AC version:
Tone C1
Tone C2
(on the driver board)
Base tone
Tone C1
Tone C2
Base tone
Tone C1
Tone C2
Base tone
Tone C1+C2
Page 9 / 11
086200000b