RISK OF INDOOR AIR
WARNING
POLLUTION!
The products described in this manual are
paraffin direct-fired, forced air heaters. Kerosene
forced air heaters are primarily intended for
use for temporary heating of buildings under
construction, alteration or repair. Direct-fired
means that all of the combustion products of the
heater enter the heated space. This appliance
is rated at 98% combustion efficiency, but does
produce small amounts of carbon monoxide.
Carbon monoxide is toxic. Humans can tolerate
CARBON MONOXIDE POISONING
WARNING
MAY LEAD TO DEATH!
only small amounts of carbon monoxide and so
precautions should be taken to provide proper
ventilation. Failure to provide proper ventilation
in accordance with the instructions in this manual
can result in death.
People with breathing problems should consult a
physician before using this heater.
Early signs of carbon monoxide poisoning
resemble the flu. Symptoms of improper
ventilation / carbon monoxide poisoning are:
Headache • Dizziness • Nausea
Sore Throat
Burning of Nose and Eyes
If you experience any of these symptoms:
GET FRESH AIR AT ONCE! Have your heater
serviced and check for proper ventilation. Some
people are more affected by carbon monoxide
than others. These include: pregnant women,
those with heart or lung problems, anemia or those
under the influence of alcohol or at high altitudes.
Not For Indoor Use. Indoor use permitted only
for the temporary heating of buildings under
construction, alteration or repair!
Provide at least a three square foot (2,800 sq
cm) opening of outside air for every 100,000
Btu / Hr heater rating. Refer to "Ventilation" on
page 7 for further instructions.
© 2020, Lavorwash
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A POWER SOURCE

Safety Information

Dry Mouth
2
WARNING
RISK OF ELECTRIC SHOCK!
ALWAYS use only the electrical power (voltage and
frequency) specified on the model plate of the heater.
ALWAYS use only approved, grounded socket and
properly rated extension cables.
ALWAYS unplug the heater when not in use.
ALWAYS install the heater so that it is not directly
exposed to water spray, rain, dripping water, or wind.
If the supply cord is damaged, it must be
replaced by a special cord or assemble available
from the manufacturer, its service agent or
similarly qualified persons in order to avoid a
hazard
RISK OF BURNS, FIRE AND
WARNING
EXPLOSION!
NEVER use fuels such as gasoline, benzine, paint
thinners or other oil compounds in this heater.
NEVER refill the heater's fuel tank while the
heater is operating or still hot. This heater is
EXTREMELY HOT while in operation.
NEVER block air inlet (rear) or air outlet (front).
NEVER use duct work in front or rear of heater.
NEVER move or handle heater while still hot.
NEVER transport heater with fuel in tank.
NEVER use with an external fuel tank.
Keep all combustible materials away from this heater.
CAUTION! HOT WHILE IN
WARNING
OPERATION. DO NOT TOUCH.
KEEP CHILDREN, ANIMALS, CLOTHING AND
COMBUSTIBLES AWAY FROM HEATER.
Minimum Clearance From Combustibles
FF45
FF70
Top
4 ft (122 cm)
4 ft (122 cm)
Sides
4 ft (122 cm)
4 ft (122 cm)
Front
8 ft (244 cm)
8 ft (244 cm)
ALWAYS locate heater on a stable and level surface.
If your heater is equipped with a thermostat,
once it is plugged in, it can start at anytime in
accordance with the thermostat setting.
Kerosene Forced Air Heater User's Manual
FF125
FF175
FF215
4 ft (122 cm)
4 ft (122 cm)
4 ft (122 cm)
4 ft (122 cm)
4 ft (122 cm)
4 ft (122 cm)
8 ft (244 cm)
8 ft (244 cm)