Quick Links

FF70
CONSUMER: READ AND SAVE THESE INSTRUCTIONS
GENERAL HAZARD WARNING:
DANGER
READ AND UNDERSTAND ALL OF THE INSTRUCTIONS IN THIS MANUAL
BEFORE ASSEMBLING, STARTING, OR SERVICING THE HEATER. Be sure to comply with the
instructions and warnings provided with this heater. Failure to comply can result in fire or explosion
that can cause property loss, bodily injury, or loss of life. Only persons who can follow and
understand these instructions should operate or service this heater.
NOT FOR USE IN RESIDENTIAL LIVING AREAS OR IN ENCLOSED SPACES
DANGER
WITHOUT ADEQUATE VENTILATION. INDOOR USE PERMITTED ONLY FOR
THE TEMPORARY HEATING OF BUILDINGS OR STRUCTURES UNDER CONSTRUCTION,
ALTERATION OR REPAIR. This is an unvented portable heater that uses air (Oxygen) from within
the area in which it is used. Failure to provide adequate combustion and ventilation air will result in
asphyxiation, carbon monoxide poisoning, bodily injury or death. Refer to "Ventilation" on Page 7.
This appliance shall be installed in accordance with the rules in force,
WARNING
and used only in sufficiently ventilated space. Consult instructions before
installation and use of this appliance.
Model Numbers
FF70 / FF125 / FF175 / FF215
FF125
© 2020 Lavorwash Australia Pty Ltd
7/76 Rushdale Street, Knoxfield, Vic. 3180
User's Manual &
Operating Instructions
FF175
FACTORY ID: 500
LWKF-400

Advertisement

Table of Contents
loading

Summary of Contents for Lavor FF45

  • Page 1 User’s Manual & Operating Instructions Model Numbers FF70 / FF125 / FF175 / FF215 FF70 FF125 FF175 CONSUMER: READ AND SAVE THESE INSTRUCTIONS GENERAL HAZARD WARNING: DANGER READ AND UNDERSTAND ALL OF THE INSTRUCTIONS IN THIS MANUAL BEFORE ASSEMBLING, STARTING, OR SERVICING THE HEATER. Be sure to comply with the instructions and warnings provided with this heater.
  • Page 2: Table Of Contents

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Table Of Contents Safety Information..........1-2 Maintenance............9-11 Features and Specifications.........3 Wiring Diagram...........11 FF45 and FF70 Assembly........4 Troubleshooting Guide........12 125 / 175 / FF215 Assembly......5-6 Exploded View...........13 Operation..............8 Parts List............14 Ventilation.............7 Safety Information FIRE, BURN, INHALATION AND EXPLOSION HAZARD.
  • Page 3: Safety Information

    COMBUSTIBLES AWAY FROM HEATER. serviced and check for proper ventilation. Some people are more affected by carbon monoxide Minimum Clearance From Combustibles than others. These include: pregnant women, FF45 FF70 FF125 FF175 FF215 those with heart or lung problems, anemia or those...
  • Page 4 240VAC / 50Hz 240VAC / 50Hz 240VAC / 50Hz 240VAC / 50Hz 240VAC / 50Hz Phase Single Single Single Single Single Specifications subject to change without notice. Features Models: FF45 / FF70 Upper Shell Hot Air Outlet Extension Handle Cord Wrap Lower Shell Fan Guard Side Cover...
  • Page 5 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Assembly Instructions Models: FF45 / FF70 Note: Save the box and packaging materials - Remove the heater and all packaging materials from the shipping carton for future storage.
  • Page 6 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Assembly Instructions Models: FF125 / FF175 / FF215 Remove the heater and all packaging Tools Needed: materials from the shipping carton. - Phillips Head Screw Driver - 8 mm open end wrench Tip: Be sure to remove the axle from the - 19 mm open end wrench side of the Styrofoam packaging.
  • Page 7 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Assembly Instructions Models: FF125 / FF175 / FF215 1. Insert axle through holes in wheel support. 10. Secure the rear handle with (2) short screws (30 mm) and (2) nuts and tighten firmly 2.
  • Page 8: Operation

    RESULT. NEVER FILL THE FUEL TANK CAUTION INDOORS. ALWAYS FILL THE TANK OUTDOORS. BE SURE THAT Minimum Ventilation Opening Needed THE HEATER IS ON LEVEL GROUND WHEN FF45 FF70 FF125 FF175 FF215 FUELING, AND NEVER OVERFILL THE TANK. 1.4 ft.²...
  • Page 9 NOTE: If if the heater still does not ignite, refer to “Troubleshooting Guide” on page 12. “Troubleshooting Guide” on page 12. NOTE: The FF45 and FF70 do not have a room temperature display feature. The room temperature display will indicate the TIP: If the heater does not ignite;...
  • Page 10: Maintenance

    Maintenance Long Term Storage: Service: Never service heater while it is WARNING Models FF45 / FF70: plugged in or hot! 1. Use an approved siphon to drain fuel through the fuel cap opening. DO NOT TAMPER WITH THE UNIT. HAVE...
  • Page 11 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Maintenance Service (Continued): SPARK PLUG: Clean and re-gap every 600 hours of operation, or FAN BLADES: replace as needed. After removing the spark plug, Blades should be cleaned at least once per clean the terminals with a wire brush.
  • Page 12: Wiring Diagram

    GREEN Models 125 / 175 / HK215FW-A FF125, FF175, FF215 GREEN have a digital display. WHITE EARTH EARTH WHITE Figure 20: FF45 Figure 21: FF70 / FF125 / FF175 / FF215 © 2020, Lavorwash Kerosene Forced Air Heater User’s Manual...
  • Page 13: Troubleshooting Guide

    Fan does not operate when heater 1. Thermostat is set too low (does not 1. Rotate thermostat to a higher is plugged in and power switch is apply to FF45 model). setting in the “ON” position. The lamp is 2. Broken electrical connection flickering or and LED display shows between main PCB and motor.
  • Page 14: Exploded View

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Exploded View 34** 35** 41** 38** 37** *FF45 / FF70 Only 39** **FF125 / FF175 / FF215 Only © 2020, Lavorwash Kerosene Forced Air Heater User’s Manual...
  • Page 15: Parts List

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Parts List ALWAYS contact the manufacturer of this heater before replacing any parts WARNING other than those specified or recommended in the servicing instructions. FF45 FF70 Part Previous Current Previous...
  • Page 16 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE FF125 FF175 Part Previous Current Previous Current Drain Bolt 70-002-0115 01.01.70.012510246 70-002-0115 01.01.70.012510246 Fuel Gauge 70-007-0210 01.04.70.012510020 70-007-0210 01.04.70.012510020 Fuel Filter 70-003-0200 01.02.70.012510020 70-003-0200 01.02.70.012510020 Fuel Cap - Large Plastic 70-006-0140 70-006-0140 70-006-0140...
  • Page 17 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE FF215 Part Previous Current Drain Bolt 70-002-0105 01.02.70.012510018 Fuel Gauge 70-007-0215 01.04.70.012510020 Fuel Filter 70-003-0200 01.02.70.012510020 Fuel Cap - Large Plastic 70-006-0140 70-006-0140 Power Cord 70-034-0270 01.04.70.412520224 Power Switch 70-038-0110 01.04.70.004510015...
  • Page 18 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________...

This manual is also suitable for:

Ff70Ff125Ff175Ff215

Table of Contents