Federal Signal Corporation ECHO E1 Installation And Maintenance Instructions Manual
Federal Signal Corporation ECHO E1 Installation And Maintenance Instructions Manual

Federal Signal Corporation ECHO E1 Installation And Maintenance Instructions Manual

Flame-proof digital intercom station
Hide thumbs Also See for ECHO E1:

Advertisement

Quick Links

Model E1
Flame-Proof
Digital Intercom Station
ATEX and IECEx
Certified
Handset Model E1-HND shown
Installation and
Maintenance Instructions
25500090A
REV. A0 1013
Printed in U.S.A.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ECHO E1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Federal Signal Corporation ECHO E1

  • Page 1 Model E1 Flame-Proof Digital Intercom Station ATEX and IECEx Certified Handset Model E1-HND shown Installation and Maintenance Instructions 25500090A REV. A0 1013 Printed in U.S.A.
  • Page 2 Industrial Systems 2645 Federal Signal Drive • University Park, IL 60484-3167 Tel: 708-534-4756 • 877-289-3246 • Fax: 708-534-4852 Email: elp@federalsignal.com • www.federalsignal-indust.com • www.fs-isys.com...
  • Page 3: Table Of Contents

    Contents Safety Messages to Installers and Users ........5 Overview of Model E1 Intercom Station .......... 6 Certifications..................8 Special Conditions for Safe Use ............8 Unpacking the Product ..............9 Mounting and Wiring the Model E1 ..........9 Safety Messages to Maintenance Personnel ........ 11 Ordering Replacement Parts ............
  • Page 4 © 2013 Federal Signal Corporation. All rights reserved.
  • Page 5: Safety Messages To Installers And Users

    Installation and Maintenance Instructions Safety Messages to Installers and Users It is important to follow all instructions shipped with this product. This device is to be installed by trained personnel who is thoroughly familiar with the country electric codes and will follow these guidelines as well as local codes.
  • Page 6: Overview Of Model E1 Intercom Station

    Installation and Maintenance Instructions Overview of Model E1 Intercom Station The Federal Signal Model E1 ECHO Intercom Stations provide safe and efficient two-way voice communications in large and small ECHO Digital Intercom Systems. The E1 is ATEX and IECEx certified for use in Hazardous Areas. The E1 ECHO station provides instantaneous high-speed connections and clear, crisp digital voice quality.
  • Page 7: Table 1 Product Specifications

    Installation and Maintenance Instructions Table 1 Product specifications Operating voltage: 24 Vdc nominal (line driven from ECHO control) Current idle: 25 mA Current connected: 100 mA max. Handset microphone type: Dynamic Handset material: Moulded polycarbonate/ABS blend. Anti-static. Handset cord: Polyeurethane Stubby microphone type: Dynamic Stubby microphone sensitivity:...
  • Page 8: Certifications

    Installation and Maintenance Instructions Certifications Models: E1-SM, E1-GM1, E1-GM2, E1-GM3, E1-HND, E1-JS Certificate nos.: ATEX Cert No.: Demko 13 ATEX 1213079X IECEx Cert No.: IECEx UL 13.0028X ATEX coding: II 2 G Protection: Ex d ib IIB T4 Gb (‒40 °C ≤ Ta ≤ +65 °C) Ex d [ib] IIB T4 Gb (for Model E1-JS) Standards: EN 60079-0: 2009, EN 60079-1: 2007,...
  • Page 9: Unpacking The Product

    Installation and Maintenance Instructions Unpacking the Product After unpacking the product, examine it for damage that may have occurred in transit. If it has been damaged, do not attempt to install or operate it. File a claim immediately with the carrier, stating the extent of the damage.
  • Page 10: Figure 2 Wiring Diagram

    Installation and Maintenance Instructions To install the Model E1 intercom: Access to internal wiring: See Figure 1 on page 9. Remove the 12 M8 stainless-steel screws securing the cover to the enclosure and carefully lift the cover. Note that the cover is attached with a bonding wire to secure it to the enclosure as well as to provide strain relief for the internal wiring.
  • Page 11: Safety Messages To Maintenance Personnel

    Installation and Maintenance Instructions Upon completion of the field wiring, secure the cover to the enclosure with the M8 screws to ensure weather- and dust- tightness and hazardous location ratings. Safety Messages to Maintenance Personnel Listed below are some important safety instructions and precautions you should follow: •...
  • Page 12: Getting Repair Service Or Technical Assistance

    Installation and Maintenance Instructions Getting Repair Service or Technical Assistance Products returned for repair require a Return Authorization form from your local distributor or from Federal Signal. To obtain repair service or technical assistance from Federal Signal, call 708-534- 4756 or 877-289-3246. For instruction manuals and information on related products, visit: http://www.federalsignal-indust.com.