Page 1
CSHH00x 1D/2D Handheld Scanners Operating Instructions Translation of the Original Operating Instruction Subject to change without notice Available as PDF version only Version: 1.0.0 Status: 12.09.2017 www.wenglor.com...
Table of Contents General ..............................6 Information Concerning these Instructions ..................6 Explanations of Symbols ........................6 Limitation of Liability ..........................7 Copyrights ............................. 7 For Your Safety ............................8 Use for Intended Purpose ........................8 Use for Other than the Intended Purpose .................... 9 Personnel Qualifications ........................
Page 3
Establishing connection ........................19 Firmware updates ..........................21 Configuration ............................22 Image capturing ..........................23 Data Matrix Code Generator ....................... 24 Setup using data matrix code .......................25 USB port .............................. 25 RS-232 Interface ..........................26 Communications Mode ........................29 Keyboard Mapping ..........................30 Alternative operating systems ......................
Page 4
9.12.22 QR Code ..........................55 9.12.23 Telepen ..........................55 9.12.24 UPC/EAN ..........................56 9.12.25 UK Plessey ..........................59 9.12.26 Straight 2 of 5 ........................59 9.12.27 Han Xin ..........................60 9.12.28 Pharmacode .......................... 60 9.12.29 Post Codes ..........................61 9.13 Other commands ..........................63 10.
• Local accident prevention regulations and national work safety regulations must be complied with as well. • The product is subject to further technical development, and thus the information contained in these operating instructions may also be subject to change. The current version can be found at www.wenglor. com in the product’s separate download area.
• wenglor assumes no liability for printing errors or other inaccuracies contained in these operating instructions, unless wenglor was verifiably aware of such errors at the point in time at which the operating instructions were prepared.
2. For Your Safety 2.1 Use for Intended Purpose This hand scanner is used to decode 1D/2D codes. This product can be used in the following industry sectors: • Automotive industry • Food industry • Packaging industry • Pharmaceuticals industry •...
• The product is not suitable for use in potentially explosive atmospheres. • The product may only be used with accessories supplied or approved by wenglor, or combined with approved products. A list of approved accessories and combination products can be accessed at www.wenglor.com on the product detail page.
2.6 Approvals 3. Technical Data Order Number CSHH001 Technical Data Optical data Scanning distance 0...200 mm Resolution 1280×960 pixels Light source Red light Max. permitted ambient light 97,000 lux Electrical data Supply voltage 5 V DC Power consumption < 2250 mW Temperature range –20…55 °C...
3.1 Scanning field / working distances Test code Minimum distance Maximal distance 0,076mm (Code 39) 25 mm 50 mm 0,190 mm (Code 39) 20 mm 150 mm 0,267 mm (GS1 DataBar) 0 mm 150 mm 0,330 mm (UPC) 15 mm 200 mm 0,107 mm ( DataMatrix) 15 mm...
3.2 Housing Dimensions 3.3 Accessory Products wenglor can provide you with suitable connection technology for your product. Suitable mounting technology no. Interface cable ZDNV001 Interface cable ZDNV002 Mains power pack ZNNN001 Mains power pack ZNNN002 3.4 Scope of Delivery • Product •...
4. Transport and Storage 4.1 Transport Upon receipt of shipment, inspect the goods for damage in transit. In the case of damage, conditionally accept the package and notify the manufacturer of the damage. Then return the device making reference to damage in transit.
5. Installation and Electrical Connection 5.1 Installation • Protect the product against contamination during installation . • Observe all applicable electrical and mechanical regulations, standards, and safety rules. • Protect the product against mechanical influences. • There must not be any objects underneath the working range . 10 Sec.
° 25 mm ATTENTION! Risk of property damage in case of improper installation! The product may be damaged. • Comply with installation instructions. CAUTION! Risk of personal injury or property damage during installation! Personal injury and damage to the product may occur. •...
• Shut down the machine. • Analyze and eliminate the cause of error with the help of the diagnostics information. • If the error cannot be eliminated, please contact wenglor’s support department • Do not operate if malfunctioning indeterminately. • The machine must be shut down if the error cannot be definitively explained or properly eliminated.
• Interleaved 2 of 5 • PDF417 • QR Code • UPC/EAN/UPC-E Additional types of codes can be activated using either the wenglor eazyScan parametrization software or the parametrization codes in chapter 9 on page 6.2 Read modes and code types Read characteristics differ from each other depending on how the code is applied, as well as the surface of the product to which the code is applied.
7. Installing the eazyScan software 7.1 Installation procedure First verify whether there is a current version of the software available on the website. Go to www.wenglor. com and download the most current version of the software, as needed. If the software on the CD is the latest version, proceed as follows: 1.
8. General setup of the eazyScan software 8.1 Start screen The following start window appears after the program has been started. Various options are provided by the software. 8.2 Operator interface The depicted layout of the operator interface shows the standard configuartion of the software upon first use. However, the user interface can be adapted to meet your individual needs.
8.3 Establishing connection 1. Open the eazyScan software 2. Plug the USB cable or RS-232 jack into your PC 3. If an RS-232 scanner is to be connected, the COM port used must be selected in the software. 4. The scanner will connect automatically. Two beeps will be heard when the scanner was connected correct- ly.
8.4 Firmware updates Click on Open file... to look for firmware files on the PC. When a firmware file has been selected, the firmware update process is started by clicking on Download file. 1D/2D Handheld Scanners...
8.5 Configuration The scanner configuration can be found under the Configuration tab. All available scanner setup parameters are displayed there. General setup of the eazyScan software...
8.6 Image capturing 1. Select the image type in which you would like to save the image. You may choose PGM or JPEG. If JPG is selected, you may also choose the image quality. 2. Position the scanner where the barcode is to be read. 3.
8.7 Data Matrix Code Generator Click on the barcode and the data matrix code generator will open. After entering the data into the free field and defining the module size of the code, generate a code by clicking on Create. General setup of the eazyScan software...
9. Setup using data matrix code 9.1 USB port The scanner is normally set to USB native mode (HID) In this mode, unformatted, unpacked data is usually sent to the scanner via the USB port. Reset to USB Factory Defaults Scan this barcode to place the reader in USB Downloader Mode.
USB Virtual COM Common Ports Scan this barcode to place the reader in bi-directional, packetized USB mode with automatic retry on pack- ets. USB Native Two Way Mode 9.2 RS-232 Interface With RS-232 communication, the scanner communicates with the host using a communication program like ESP Terminal.
Page 28
Parity (RS-232) Parity is an error detection routine in which every character in a data bit is set to 1 or 0 so that the total num- ber of 1 bits in each data fi eld is even or odd. It only needs to be changed when the host settings need to be adjusted.
RS232 Interface Flow Control Off RS232 Interface Flow Control - Hardware 9.3 Communications Mode Data is transmitted from the scanner to the host in raw format, without packet framing or check characters. One-way communication is conducted in raw format. No response from the host is expected and data will not be resent.
9.4 Keyboard Mapping The Keyboard Mapping option provides alternative settings for keyboards that do not have the US English keyboard layout. Note: The universal keyboard layout is somewhat slower than other language-specifi c options since the keys are assigned using the entire ASCII character set. The advantage of the universal keyboard layout is that every language and keyboard layout can be mapped.
Page 31
Keyboard Support: English (UK) Keyboard Mapping for Windows Keyboard Support: Belgian French Keyboard Mapping for Windows Keyboard Support: French Keyboard Mapping for Apple Keyboard Support: French Keyboard Mapping for Windows Keyboard Support: German Keyboard Mapping for Apple 1D/2D Handheld Scanners...
Page 32
Keyboard Support: German Keyboard Mapping for Windows Keyboard Support: German-Swiss Keyboard Mapping for Apple Keyboard Support: Swiss German Keyboard Mapping for Windows Keyboard Support: Italian Keyboard Mapping for Apple Keyboard Support: Spanish Keyboard Mapping for Apple Setup using data matrix code...
Page 33
Keyboard Support: Spanish Keyboard Mapping for Windows Keyboard Support: Japanese Keyboard Mapping for Windows Keyboard Support: Latin American Keyboard Mapping for Window USB HID POS Mode (Terminal ID 131) Translate all Characters to Uppercase Off 1D/2D Handheld Scanners...
9.5 Alternative operating systems The reader will modify its enumeration and communication scheme to work on Linux, Windows CE, or OS X operating systems. Alternative operating systems (Linux/Mac) off (Standard) Alternative operating systems (linux/Mac) on 9.6 Scanning process When on, reader will constantly fl ash its LEDs and attempt to decode. Turn on to disable this feature. Contin- ues Read off.
Page 35
1 Second Duplicate Scan Delay 2 Second Duplicate Scan Delay 3 Second Duplicate Scan Delay 5 Second Duplicate Scan Delay 10 Second Duplicate Scan Delay 30 Second Duplicate Scan Delay 1 Hour Duplicate Scan Delay 1 Day Duplicate Scan Delay 1D/2D Handheld Scanners...
Page 36
You can activate and deactivate LED alignment assistance using the Targeting parameter. Alignment assis- tance is activated by default. Targeting On (Standard) Targeting On Use Motion Detection to specify that the scanner start a decoding trial as soon as it detects movement in its visual fi eld.
Motion Detection On in Stand Trigger out of Stand Motion Detection On In and Out of Stand 9.7 Dual scanning area The scanner can read small 2D codes as well as large 1D codes thanks to its dual scanning area. An image will be captured of every area.
Scan this barcode to read from the wide optical fi eld only Scan this barcode to read from the high density optical fi eld only Scan this barcode to read from both optical fi elds. 9.8 Mirroring The scanner can decode mirrored symbols with the Mirroring function. When Mirroring is active, all other decoding functions are turned off.
9.9 Preamble and postamble attached at the beginning of a decoded data string. The characters are displayed in the order that they are activated (from left to right). If you, for example, enter a comma and then a space, then decode a barcode with the “ABC”...
Page 40
Suffi x Space Suffi x Tab (USB Keyboard Mode Only) Suffi x Enter (USB Keyboard Mode Only) Suffi x Carriage Return (RS232 Mode Only) Suffi x Line Feed (RS232 Mode Only) Suffi x Carriage Return Line Feed (RS232 Mode Only) Suffi x Tab (RS232 Mode Only) Erase Prefi x &...
Turn on Timestamp Prefi x Turn off Timestamp Prefi x 9.10 Text Command Use Text Command to determine whether a text command from the host is to be received. Reader Text Commands Off (Standard) Reader Text Commands On 9.11 Beeper / Vibrator Press the confi guration symbols below in order to activate or deactivate the beeper and vibrator functions.
Page 42
Beep On Vibrate Off Beep Off Vibrate Off Beep Volume 0 % Beep Volume 33 % Beep Volume 67 % Beep Volume 100% Setup using data matrix code...
9.12 Code settings 9.12.1 Aztec Code Aztec On (Standard) Aztec Off Aztec Inverse On Aztec Inverse & Normal On 9.12.2 Codabar Codabar On (Standard) Codabar Off Codablock F Off 1D/2D Handheld Scanners...
Codablock F On Keep Codabar Start and Stop Delimiters – Default Remove Codabar Start and Stop Delimiters 9.12.3 Code 11 Code 11 Off (Standard) Code 11 On Code 11 Checksum Stripped from Result On Enable Code 11 Decoding with one checksum digit checked, and remove checksum from output Setup using data matrix code...
9.12.4 Code 32 (Italian Pharmacode) Code 32 (Italian Pharmacode) Off (Standard) Code 32 (Italian Pharmacode) On 9.12.5 Code 39 Code 39 On (Standard) Code 39 Off Code 39 Checksum Off Code 39 Checksum On Code 39 Checksum Stripped from Result On 1D/2D Handheld Scanners...
Code 39 Extended Full ASCII Off Code 39 Extended Full ASCII In 9.12.6 Code 49 Enable Code 49 Disable Code 49 9.12.7 Trioptic Barcode Trioptic Off (Standard) Trioptic On Trioptic - Disable Reverse Order option (Bit 3) Setup using data matrix code...
9.12.10 Composite Barcode Composite off (Standard) Composite on 9.12.11 Data Matrix Data Matrix Rectangular & Rectangular Extended Off Data Matrix Rectangular On & Rectangular Extended Off (Standard) Data Matrix Inverse Off Data Matrix Inverse On (Standard) Data Matrix Rectangular On & Rectangular Extended On Setup using data matrix code...
9.12.13 GoCode Enable GoCode & GoCode Inverse Decoding Enable GoCode & GoCode Mirror Decoding Enable GoCode, GoCode Inverse & GoCode Mirror Decoding 9.12.14 GS1 Databar All GS1 DataBar On (Standard) All GS1 DataBar Off GS1 DataBar Limited On GS1 DataBar Omnidirectional and GS1 DataBar Truncated On Setup using data matrix code...
Page 51
GS1 DataBar Stacked and GS1 DataBar Stacked Omnidirectional On GS1 DataBar Expanded On GS1 DataBar Stacked and GS1 DataBar Stacked Omnidirectional Off GS1 DataBar Limited Off GS1 DataBar Omnidirectional and GS1 DataBar Truncated Off GS1 DataBar Expanded Stacked Off GS1 DataBar Expanded Stacked On GS1 DataBar Expanded Off 1D/2D Handheld Scanners...
9.12.15 Interleaved 2 of 5 Interleaved 2 of 5 On (Standard) Interleaved 2 of 5 Off Int 2 of 5 Checksum Off (Standard) Int 2 of 5 Checksum On Int 2 of 5 Checksum Stripped from Result On 9.12.16 Maxicode Maxicode Off (Standard) Maxicode on Setup using data matrix code...
9.12.17 Matrix 2 of 5 Matrix Code 2 of 5 Off (Standard) Matrix Code 2 of 5 On 9.12.18 PDF417 PDF417 On (Standard) PDF417 Off Micro PDF417 Off (Standard) Micro PDF417 On 1D/2D Handheld Scanners...
9.12.19 MSI Plessey MSI Plessey On MSI Plessey Off (Standard) 9.12.20 Hong Kong 2 of 5 Hong Kong 2 of 5 Off (Standard) Hong Kong 2 of 5 On 9.12.21 NEC 2 of 5 NEC 2 of 5 on NEC 2 of 5 off Setup using data matrix code...
9.12.22 QR Code Standard QR Code On (Standard) All QR Code on All QR Code Off 9.12.23 Telepen Telepen On Telepen Off (Standard) Output Telepen as Numeric Output Telepen as ASCII 1D/2D Handheld Scanners...
9.12.24 UPC/EAN UPC On Scanner reads UPC-A, UPC-E, EAN-13 and EAN-8 UPC Off UPC E Expansion Off (Standard) Scanner expands UPC-E bar codes into UPC-A barcodes UPC E Expansion On Scanner expands UPC-E bar codes into UPC-A barcodes UPC Supplemental Off (Standard) Reader will scan the two or fi ve digit supplemental barcode that accompanies some UPC/EAN barcodes UPC Supplemental On Reader will scan the two or fi ve digit supplemental barcode that accompanies some UPC/EAN barcodes...
Page 57
Do Not Transmit UPC-A Check Digit Transmit UPC-A Number System Do Not Transmit UPC-A Number System Transmit UPC-E Check Digit Do Not Transmit UPC-E Check Digit Transmit UPC-E Number System Do Not Transmit UPC-E Number System Transmit EAN-13 Check Digit 1D/2D Handheld Scanners...
Page 58
Do Not Transmit EAN-13 Check Digit Transmit EAN-8 Check Digit Do Not Transmit EAN-8 Check Digit Do Not Convert EAN-8 to EAN-13 Convert EAN-8 to EAN-13 Do Not Convert UPC-A to EAN-13 Convert UPC-A to EAN-13 Do Not Convert Bookland EAN-13 to ISBN Setup using data matrix code...
Convert Bookland EAN-13 to ISBN Do Not Convert Bookland EAN-13 to ISSN Convert Bookland EAN-13 to ISSN 9.12.25 UK Plessey UK Plessey Off (Standard) UK Plessey ON 9.12.26 Straight 2 of 5 Straight 2 of 5 Off (Standard) Straight 2 of 5 On 1D/2D Handheld Scanners...
9.12.27 Han Xin an Xin On Han Xin Off (Standard) 9.12.28 Pharmacode Pharmacode Off (Standard) Pharmacode On Pharmacode Reverse Barcode Decoding (Right to Left) Pharmacode Normal Barcode Decoding (Left to Right) Setup using data matrix code...
9.12.29 Post Codes USPS Postnet On USPS Postnet Off (Standard) USPS Planet On USPS Planet Off (Standard) USPS Intelligent Mail/IMB/ 4-State CB On USPS Intelligent Mail/IMB/ 4-State CB Off (Standard) Australian Post On Australian Post Off (Standard) 1D/2D Handheld Scanners...
Page 62
KIX (Dutch Post) Code On KIX (Dutch Post) Code Off (Standard) Japan Post On Japan Post Off (Standard) UK Royal Mail On UK Royal Mail Off(Standard) Korean Post On Korean Post Off (Standard) Setup using data matrix code...
Universal Postal Union ID-Tag On Univeral Postal Union ID-Tag Off (Standard) 9.13 Other commands Clear All Stored Data and Images Clear all JavaScript Rules Reader ID and Firmware Version Save settings Save All Reader Settings Cell Phone Reading Enhancement Off (Standard) 1D/2D Handheld Scanners...
Page 64
Cell Phone Reading Enhancement On Scan this barcode to translate all alphabetic data to upper case Convert Barcode Data to Lowercase Control Character Input - Language Default - Default Control Character Input - Ctrl + Character Control Character Input - Alt + Keypad Control Character Input -Alt + Leading Zero Output Good Read on RTS line Off Setup using data matrix code...
• The product must be protected against contamination during initial start-up 11. Proper Disposal wenglor sensoric GmbH does not accept the return of unusable or irreparable products. Respectively valid national waste disposal regulations apply to product disposal. 1D/2D Handheld Scanners...
12. Appendix 12.1 List of Changes to Operating Instructions Version Date Description/change Associated software version September 2017 1.0.0 Initial version of the ope- rating instructions 12.2 Check list for initial start-up • This checklist is intended to provide assistance during initial start-up. •...
12.3 EU Declaration of Conformity The EU declaration of conformity can be found on our website at www.wenglor.com in download area. 1D/2D Handheld Scanners...
Need help?
Do you have a question about the CSHH001 and is the answer not in the manual?
Questions and answers