Advertisement

Quick Links

RS AdriaⅡ
Thank you for purchasing this Takara Belmont product.
The instructions contained in this booklet should be thoroughly read and understood
before use.
Using this product before reading this operating manual may result in an accident.
This product is an industrial shampoo unit designed for barbers and hair salons.
Only use this product for its intended purpose and do not use it for non-hairdressing work.
Keep this manual and refer back to them when required.
RS Adria II
Operating Manual

Table of Contents

This product is designed for shampooing and hair/scalp care.
Version 1
1
2
2
5
8
8
8
9
9
9
10
10
11
16
22
22
22
23
23
24
24
25
26
27
April 2016

Advertisement

Table of Contents
loading

Summary of Contents for Takara Belmont RS Adria II

  • Page 1: Table Of Contents

    Specifications Dimensions Procedures for Daily Inspections Thank you for purchasing this Takara Belmont product. The instructions contained in this booklet should be thoroughly read and understood before use. Using this product before reading this operating manual may result in an accident.
  • Page 2: Description Of Warning Symbols

    Description of Warning Symbols booklet should be thoroughly read and understood before use. The precautions listed here are to ensure that this product can be used safely, and to prevent any danger or risk to the person using this product or those around them. responsible for any damage or risk to the person using this product or those around them due to accidents if this product provided below.
  • Page 3 Warning Do not use hot water (boiling water) Adhere to the following when of 60 or higher. operating the seat. CAUTION Hot water Disassembly and repairs/modifications are prohibited. Disassembly Prohibited Adjust the water temperature while checking the temperature by hand. Return the temperature control knob to an appropriate position after using Do not lean on the basin...
  • Page 4 Caution Do not hit the unit with objects. Do not touch the hot water supply pipe or mixing pipe. Do not hit the unit with hard objects. Failure to follow this instruction may cause deformation or The hot water supply pipe or mixing pipe may damage to the unit.
  • Page 5: Precautions For Use

      Precautions for Use Caution Set the water temperature for this Do not use peppermint or aroma oil. product to 80 or less. Do not use peppermint or aroma oil containing Failure to follow this instruction may cause malfunctions menthol. Failure to take this precaution may or damage in parts such as the stop valve, check valve, damage the resin parts, such as the flexible pipe and thermostat water valve.
  • Page 6 Caution Do not wet the shower head bracket Do not strike the resin (plated) parts with water. with a hard object. Do not wet the shower head bracket with water. Do not strike the resin (plated) parts, such as the Failure to follow this instruction may cause water water stop knob and temperature control knob leaks.
  • Page 7 Caution Do not leave the shower head Do not drop heavy objects on to the basin. immersed in water. Do not place or drop heavy objects on to the If pressure in the water pipes decreases due to basin. Failure to follow this instruction may cause repairs that follow water stoppages, the water in damage such as scratches or cracks to the basin.
  • Page 8: Precautions For Handling Synthetic Leather

    Precautions for Handling Synthetic Leather Handling precautions Stains caused by clothing dyes The synthetic leather of this product may become stained by direct contact with clothes or belts. If there is stains, wipe clean as quickly as possible with a 10% detergent solution diluted using water to prevent permanent staining. Take care of deformation or stains due to direct contact •...
  • Page 9: Before Using This Product

    Caution before using the product. If peeling is observed, immediately stop using the product and contact your closest dealer or Takara Belmont. Continued operation may result in injuries. E x a m ple of F la ws on the P la t e d S ur f ac e...
  • Page 10: Accessories

    Accessories Neck cushion…1 Hair catcher…1 Trickle stopper rubber…1 Manual…1 Setting sheet…1 …1 Stopper Rubber …1 Preparations Attach neck cushion on the basin Chair Side As shown in the illustrations, check the proper Chair Side direction of the neck cushion and fit it to the basin along the basin edge.
  • Page 11: How To Use

    How to use RS Adria II Allow the customer to be seated in the chair and then apply the shampoo cloth. The customer may place the feet on the step as required. When seated, inform the customer not to place any weight on the backrest in advance.
  • Page 12 Drain cap notice water discharge, thus resulting in water leaks. (PRIME,ELITE, RS Adria II) Rotate the basin adjustment screw provided on the main unit with the supplied hexagonal-head wrench Basin Adjustment Screw and set to an adequate position. The screw is provided on the right and the left sides.
  • Page 13 Changing the selection switch position switches between shower water discharge and air bubble water discharge. Protrusion Selection Switch <Shower Water Discharge> <Air Bubble Water Discharge> Showerhead Press the switch on the side Press the switch on the flat side. Water Spray Plate with the protrusion.
  • Page 14 Adjusting the water temperature (excluding AY-P073X,AY-074X) Turn the temperature control knob in the H or C direction to set the temperature to an appropriate level. (C) Cold When adjusting the water temperature, reduce the (H) Hot volume of water, point the shower head away from Caution the customer and check the temperature by hand.
  • Page 15 Drain cap Shower Hose Slot To accumulate hot water for emulsification of hair color, rotate the drain cap in the clockwise direction to close the drain outlet. The amount of water should be below the level shown by the dotted line in the illustration on the right (just below the shower hose slot).
  • Page 16: Maintenance

    Maintenance Never use volatile chemicals such as thinners, alcohol, gasoline or kerosene, cleaning products such as abrasire wax , a sponge with a scourer, detergents that include organic solvents, Caution acidic, alkaline or chlorine-based detergents, or scouring pads. Failure to follow this instruction may cause scratches or discoloration.
  • Page 17 Wipe any dirt clean using detergent diluted with water. Area of Fixing Pins If streaked scratches appear due to contact with metallic objects such as watch bands, rub the area with a nylon scourer. Do not use a metallic scourer or sandpaper, Caution as this will damage the basin.
  • Page 18 The product is provided with a water catcher to prevent water leaks from the neck area trickling onto the cover or the floor when shampooing. The amount of water that can accumulate in the water catcher is limited. Be sure to wipe off the water or clean the catcher to prevent contamination after finishing shampooing.
  • Page 19 Rotate and loosen the air bubble fixture with the wrench. Loosening Remove the three parts (rubber gasket, air bubble unit, and air bubble fixture) and wash with water using a nylon or similar brush. The air bubble unit should be rinsed with running water in the direction shown in the illustration below: Tightening Running Water...
  • Page 20  excluding AY-P073X,AY-P074X To use the basin for a long period of time, clean the strainer (inside the check valve) regularly. If temperatures are expected to drop below freezing in cold regions, drain the water from the check valve. In cold regions, always drain the water as a measure to prevent freezing.Failure to follow this Caution instruction may cause water leakage.
  • Page 21 Close the hot water and water stop valves. To prevent water leakage, always check that the stop valves are completely closed Caution before cleaning or draining the water from Check Valve the strainer. Loosen Attach Clean the strainer. When the strainer is detached, the water in the pipe will come Tighten Detach out.
  • Page 22: Daily Inspections

    Daily Inspections To ensure that this product can be used for a long period of time, follow the procedures outlined in accidents. Parts Replaced on a Regular Basis The following are parts that must be replaced on a regular basis as designated by our company: -For the drain hose, there is a possibility that water leaks will occur because cracks are caused due to deterioration and hardening of the hose from chemical agents in the drain water.
  • Page 23: Before Requesting Repairs

    Before Requesting Repairs If the following problems arise, conduct the checks outlined before requesting repairs. Symptom Check this Solution Is the water stop faucet of the Open the water stop faucet. Water does not come out. (See pages 20 and 21.) pipe open? Is the temperature setup of the Adjust the temperature setup of the...
  • Page 24: Disposing Of This Product

    Disposing of This Product When disposing of this product or replaced parts, adhere with current regulations and dispose of them appropriately. After-sales Service To request after-sales service, contact your closest dealer or Takara Belmont (UK) LTD directly.
  • Page 25: Specifications

    Within 0.2 MPa (2kgf/cm Weight Main unit Basin free tilt type 42.0kg Chair Chair(RS Adria II) 16.2kg Chair (PRIME) 17.0kg Chair (ELITE) 18.5kg *For details of the hot-water supply temperature, hot-water/water supply pressures, see the RS Adria II Installation Instructions.
  • Page 26: Dimensions

    Product Dimensions RS Adria II [Unit: mm] Top View Side View Center of Drain Pipe Practice in Standing Posture: 600 or over, Sitting Posture: 630 or over 1525 Standing Posture: 2560 or over; Sitting Posture: 2590 or over...
  • Page 27: Procedures For Daily Inspections

    Procedures for Daily Inspections To ensure that this product can be used for a long period of time, conduct the inspections below. Inspect the product every day Inspection item Inspection method If the inspection results show defects Is the plating of the Visually check the water stop knob Flaws, cracks, or peeling of the plated surface water stop knob and...
  • Page 28 Procedures for Daily Inspections (Continued) To ensure that this product can be used for a long period of time, conduct the inspections below. Inspection method Inspection item If the inspection results show defects Does the temperature Turn the temperature control knob, control knob work check that the water temperature is properly or if there is abnormal noise, there may...

Table of Contents