■Program using module FB
Program as follows when using the module FB
• Devices used
Device
SB0047
M150
M151
M152
M154 to M156
D352 to D355, D359 and D368
D750 to D753
• Instance name of module FB
Name of module FB
M+FX5CCLIEF_Send
• FX5-CCLIEF module label
Module label name
FX5CCLIEF_1
• Label to be used
Label name
■Input label
i_bEN
i_stModule
i_uTargetNetworkNo
i_uTargetStationNo
i_uChannel
i_uTargetChannel
i_uDataLength
i_uSendData
■Output label
o_bENO
o_bOK
o_bErr
o_uErrId
■Public label
pbi_uMonitorTime
8 DEDICATED INSTRUCTION
86
8.2 Link Dedicated Instructions
Description
Baton pass status of own station
Setting command of module FB
Send data setting command
Execution command of module FB
Bit-type input output label for module FB (Refer to the following table for the setting.)
Word-type input output label for module FB (Refer to the following table for the setting.)
Send data storage device (station No. 1)
Instance name
Send
Module No.
No.1
Item
Execution command
Module label
Target network number
Target station number
Own station channel
Target station data storage channel
Send data length
Send Data Storage Device
Execution status
Normal completion
Abnormal end
Error code
Arrival monitoring time
Setting value/setting device
FX5CCLIEF_1
1 (D354)
2 (D355)
1 (D352)
2 (D353)
4 words (D359)
D750
M154
M155
M156
D368
0 (10 seconds)