Self Diagnosis

Message
MOTOR TP
VOID
VOID
OPEN TORQUE
CLOSE TORQUE
OVER LIMIT
UNDER LIMIT
POT LOSS
POT REV
VOID
- 10 -
Hove To Solve
MOTOR OVERHEATING
( 150°C TP Open )
Restart
OPEN OVER TORQUE
Restart
Valve Check
CLOSE OVER TORQUE
Restart
Valve Check
OPEN LIMIT SWITCH FAILURE
Open Limit Switch Resetting
CLOSE LIMIT SWITCH SETTING
Close Limit Switch Resetting
POTENTIOMETER LOSS
After checking wiring of potentiometer
REVERSE POTENTIOMETER
After checking wiring of potentiometer
Change 2 lines in P1, P3