Trane RTAA Installation Operation & Maintenance

Trane RTAA Installation Operation & Maintenance

Air-cooled helical rotary liquid chillers
Hide thumbs Also See for RTAA:

Advertisement

Installation
Operation
Maintenance
This manual should be used jointly
with the manual of the UCM-CLD
reference L80 IM 025 E
C
IM
E
20
004
RTAA/RTAB
Air-Cooled Helical Rotary
Liquid Chillers

Advertisement

loading

Summary of Contents for Trane RTAA

  • Page 1 RTAA/RTAB Air-Cooled Helical Rotary Liquid Chillers Installation Operation Maintenance This manual should be used jointly with the manual of the UCM-CLD reference L80 IM 025 E...
  • Page 2: Foreword

    Trane sales office. Specify any damage on the delivery note, and send a regis- tered letter of protest to the last carrier of the goods within 72 hours of delivery. Notify the local Trane sales office at the same time. General information...
  • Page 3: Table Of Contents

    Table of contents Foreword ..............................2 Warranty..............................2 Reception..............................2 General ..............................2 Refrigerant..............................2 Installation General information ..........................4 Installation..............................7 Clearances ..............................8 Lifting procedure ...........................11 Water piping............................11 Freeze protection...........................14 Operation Operating principles ..........................15 Refrigeration cycle..........................15 Oil system...............................18 Remote CLD panel wiring ........................19 Pre-start procedure..........................21 Start-up procedure ..........................22 Shut-down procedure ...........................23 Maintenance Maintenance............................24...
  • Page 4: General Information

    Concealed damage for proper control operation before shipment. must be reported within 15 days. Figures 1 thru 3 show a typical RTAA/RTAB unit and its - If concealed damage is discovered, stop unpacking the components. Table 1 contains general RTAA/RTAB mecha- shipment.
  • Page 5 Figure 2 - Starter and control panels Figure 3 - Starter and control panels...
  • Page 6 Table 1A : General data on units R22 (standard units) Model RTAA Nominal Cooling Capacity (1) (kW) 1036 1140 Number of Circuit Number of Compressor Maximum FLA 400/50/3 (2) Number of fans Fan Motor Size (3) (kW) 1.21/0.85 1.21/0.85 1.21/0.85 1.21/0.85 1.21/0.85 1.21/0.85 1.21/0.85 1.21/0.85 1.21/0.85 1.21/0.85 1.21/0.85...
  • Page 7 (kg) 40 18/18 23/23 24/24 24/24 29/29 Table 1C : General data on units R134a (standard units) Model RTAA Nominal Cooling Capacity (1) (kW) Number of Circuit Number of Compressor Maximum FLA 400/50/3 (2) Number of fans Fan Motor Size (3) (kW) 1.21/0.85 1.21/0.85 1.21/0.85 1.21/0.85 1.21/0.85 1.21/0.85 1.21/0.85 1.21/0.85 1.21/0.85 1.21/0.85 1.21/0.85...
  • Page 8 Société Trane - Société Anonyme au capital de 41 500 000 F - Route de Chamagne - 88130 Charmes - France - Siret 306 050 188-00011 - RCS Epinal B 306 050 188 - Numéro d'identification taxe intracommunautaire : FR 83 306050188...