Page 1
PSB- series Operating manual 1. Specifications and performance Model PSB-75 PSB-150 PSB-300 PSB-300B Capacity 75kg 150kg 300kg 300kg (0.1~5kg)/10g (0.2~10kg)/20g (0.5~20kg)/50g (0.2~75kg)/20g Resolution (5~75kg)/20g (10~150kg)/50g (20~300kg)/100g (75~150kg)/50g (150~300kg)/100g 50kg 100kg 200kg 300kg Calibration weight Dimension of 400*400*50mm platform Power Supply AC/DC ADAPTOR Input AC100-240V Output DC6V/300mA Or: 4 pieces 1.5V AA batteries 2.Shape and installation of scale:...
Page 2
3.Operation method: 3.1 General information and setup After transporting the scale from a cold place to warm room let it rest for 15 minutes without power supply to avoid damages at electronic components due to condensation. Place the scale on a solid and level ground. Soft ground (carpet) or a table that bends if a heavy weight is placed on the board, can cause wrong results.
Page 3
3.2.4 “COUNT” count key: sampling of article by “COUNT” key to enter the counting state (1) Choose the quantity of samples: To precisely count the articles, firstly the quantity of samples for counting should be chosen in according with the weights of the articles. The quantity of samples can be chosen from “1-10-20-50-100”.
Page 4
Overview: In the off state press the [CAL] button and keep it pressed, press the [ON/OFF] button turn on the balance. Now the balance is starts in the setting mode. The [CAL] button changes the setting (C1 to C2). Press the [TARE] button to change the setting value (C1---0 to C1---1).