Waterbird ITSC1000 User Manual page 6

Table of Contents

Advertisement

Multi Slider – User Manual
If the blue LED Indicator is flashing the Control Unit is waiting for a connection to a Control
device (e.g. Smartphone or Tablet).
If the blue LED Indicator is constantly on, the Control Unit is connected and ready to be used.
4) USB Connector
The USB connector can be used to control the Control Unit via a PC (Software planned to be
released in the future) and for firmware updates. Powering the Control Unit via USB is only
possible for firmware updates, no Motor control is possible if no power is available on the
Supply DC Connector.
Auxiliary Connector
5)
This Port can be used to connect accessories like a manual knob or external controls e.g. to
control a light that is switching on and off before and after the picture taken for long duration
time-lapse.
6) Reset + Motor Off Button
This button can be pressed to reset the internal processor of the Control Unit. This causes also
a sudden stop of all connected Motors. You can use it if the System does not react as desired
to prevent from damaging equipment. Please take care that the Motors will not be powered
after pressing. And in case of vertical usage and high load the carriage could be pulled down
by gravity. After pressing the button the initialization of the slider needs to be repeated via
the App.
Copyright © 2017 Waterbird Systems GmbH
www.waterbird.at
- 3 -